Thermocouple: K type 1/4"OD x 18" L with Alloy Sheath, Detective Probe and Male Plug for Calibration - TC-K-Cali-18S-RTP-LD

Thermocouple: K type 1/4"OD x 18" L with Alloy Sheath, Detective Probe and Male Plug for Calibration - TC-K-Cali-18S-RTP-LD

RM0.00 MYR
Sale price  RM0.00 MYR Regular price 
Skip to product information
Thermocouple: K type 1/4"OD x 18" L with Alloy Sheath, Detective Probe and Male Plug for Calibration - TC-K-Cali-18S-RTP-LD

Thermocouple: K type 1/4"OD x 18" L with Alloy Sheath, Detective Probe and Male Plug for Calibration - TC-K-Cali-18S-RTP-LD

SKU: tck18srtp

Price: RFQ

Description

Features: Super Accurate, Super Stable, Super Value For Use with Temperatures Up to 1335 o C (2440 o F) FOR OTF-1200X-RTP-II Excellent Long Term Stability at High Temperature Nickel-Chrome Based Super-alloy Sheathing Provides Excellent High Temperature Performance Detective probe make temperature  measure much more precise measurement. Excellent Oxidation, Carburization and Chlorination Resistance Made with materials of Special Limits of Error.  Perfect for calibrating MTI tube furnaces using a precision temperature calibrator (matched with male plug; related product below )

Specifications

  • Length:                           18"
  • Diameter of sheath:         1/4" diameter
  • Positive Material:             Ni-Cr
  • Negative:                        Ni-Al
    Highest Temperature:     1200  oC
    Material:           Ni-Al
  • Lowest Temperature:     -200 oC
1/4" thermocouple can be inserted into processing tube via flange
and calibrating tube furnace temperature under vacuum *( click picture to order the flange)
Application Notes
  • If necessary, please check out K type thermocouple extension wire with mini male plugUsing compensating wires is equivalent to stretching them to keep them operating at a constant temperature. The advantages of using compensating cables are saving material costs and solving the problem of constant temperature, etc.
  • There are 2 polarities for K type thermocouple: positive and negative. Please check polarity of K type thermocouple before use. Wrong polarity may cause temperature measuring error.
  • It is also easy to test the polarity of K type thermocouples. The negative wire is MORE magnetic than the positive wire. Just put a magnet up to each wire. One will be more magnetic than the other.
Warning
  • Chromel/Alumel is vulnerable to sulfidic corrosion which can result in a thermocouple failure. Apply a thin layer of Zirconia coating will protect the TC from corrosion and thus extend its service life. Re-apply the coating if there is a sign of layer flaking/peeling after the process. Please click the picture in below to order the product.