{"product_id":"tube-hp-85-50-1000","title":"Hi-Pressure Super Alloy Tube: 85ODx50 IDx1000L (mm) w\/ Flange, 1100°C Max. - Tube-HP-85-50-1000","description":"Please view \" Isotropic round-wire multifilament cuprate superconductor for generation of magnetic fields above 30 TMat-2014-13-4-Larbalestier-Isotropic round-wire \" published by NATURE MATERIAL 3887, 9 MARCH 2014, in which an MTI High-Pressure furnace was used. Ni-based superalloy tube vessel ( 85 OD x 50 ID x 1000 L mm). It can be used under ultra-highly oxidizing and inert gas atmosphere up to 1100°C to process special compounds. It is a consumable part of OTF-1200X-HP-III, which is a compact HIP (hot isostatic pressure) furnace for researching the new generation of materials at a low cost. Specification: Tube Dimensions O.D. 85 mm      I.D. 50mm     Length: 1000mm Inside Diameter: 50 mm Tube Length: 1000 mm Max.Working Temperature without Load: 1100 °C Working Pressure \u0026amp; Temperature: Maximum pressure inside the tube Heating temperature Max. 1958 PSI  (13.5Mpa)    (140 Bar) 800°C Max. 1189 PSI  (8.2 Mpa)    (80 Bar) 900°C Max. 595  PSI  (4.1 Mpa)     (40 Bar) 1000°C Max. 362  PSI  (2.5 Mpa)     (25 Bar) 1100°C (for \u0026lt;1hr) Warning : Please set up a pressure alarm point in the digital pressure display before the operation Must install a pressure regulator on the gas cylinder to increase pressure gradually. Service-life design for 2,000 hours at 800oC. The high-pressure vessel is a consumable part, please order replacement once found deformation Pressure Gauge A digital Vacuum\/Pressure Gauge is included with alarm function Pressure Limits for gauge: -100 Kp  to 0  and to 30MPa (Vacuum to Atmosphere to Positive Gas Pressure) Installation: Water Cooling There are four water-cooling bracket blocks, two on each side. Two water cooling ports on each block. Illustration of linking all four half-water cooling blocks in series. Option Water Cilller Must have a water chiller while heating this tube, or it will cause damage to the flanges. A water chiller is required, but not included, please click to order at extra cost. Recommended Optional Tool Please use a torque wrench to make sure the equal forces to be applied to the bolts when installing the CF flange in MTI high-pressure furnace. Hex Bit Socket M14 of Torque wrench for CF flange installation CFTQ-M14\u003cbr\u003e\u003cbr\u003e\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eTube Dimensions\u003cbr\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv style=\"text-align: start;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/Tube-HP-85-50-1000_Front.jpg?v=1706135418\" target=\"_blank\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/Tube-HP-85-50-1000_Front_100x100.jpg\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003c\/a\u003e\u003c\/div\u003e\n O.D. 85 mm      I.D. 50mm     Length: 1000mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInside Diameter: \u003c\/td\u003e\n\u003ctd\u003e50 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTube Length:                   \u003c\/td\u003e\n\u003ctd\u003e1000 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan\u003eMax.Working Temperature\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003ewithout Load:  \u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e1100 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan\u003eWorking Pressure\u003c\/span\u003e\u003cspan\u003e \u0026amp; \u003cbr\u003eTemperature:\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum pressure inside the tube\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003eHeating temperature\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. 1958 PSI  (13.5Mpa)    (140 Bar)\u003c\/td\u003e\n\u003ctd\u003e800°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. 1189 PSI  (8.2 Mpa)    (80 Bar)\u003c\/td\u003e\n\u003ctd\u003e900°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. 595  PSI  (4.1 Mpa)     (40 Bar)\u003c\/td\u003e\n\u003ctd\u003e1000°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. 362  PSI  (2.5 Mpa)     (25 Bar)\u003c\/td\u003e\n\u003ctd\u003e1100°C (for \u0026lt;1hr)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cspan style=\"color: rgb(255, 42, 0);\"\u003e\u003cstrong\u003eWarning\u003c\/strong\u003e\u003cstrong\u003e: \u003c\/strong\u003e\u003c\/span\u003e\n\u003cul\u003e\n\u003cli style=\"color: rgb(255, 42, 0);\"\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003ePlease set up a pressure alarm point in the digital pressure display before the operation\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"color: rgb(255, 42, 0);\"\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003eMust install a pressure regulator on the gas cylinder to increase pressure gradually.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"color: rgb(255, 42, 0);\"\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003eService-life design for 2,000 hours at 800oC. The high-pressure vessel is a consumable part, please order replacement once found deformation\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003ca href=\"DHPG\" target=\"_blank\"\u003e\u003cspan\u003ePressure Gauge\u003cbr\u003e\u003cimg class=\"product-list-img\" height=\"48\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/HPG6Main.jpg\" style=\"float: left; border: 1px solid black;\" width=\"72\"\u003e\u003c\/span\u003e\u003c\/a\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eA digital\u003ca href=\"dhpg\" target=\"_blank\"\u003e Vacuum\/Pressure Gauge\u003c\/a\u003e is included with alarm function\u003c\/li\u003e\n\u003cli\u003ePressure Limits\u003cspan class=\"Apple-tab-span\"\u003e \u003c\/span\u003efor gauge: -100 Kp  to 0  and to 30MPa (Vacuum to Atmosphere to Positive Gas Pressure) \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Installation:\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv style=\"text-align: start;\"\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/Conflat_flange-1.jpg?v=1742577880\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/Conflat_flange-1_100x100.jpg\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003c\/a\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003e     \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/DSC_1882.jpg?v=1706219937\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/DSC_1882_100x100.jpg\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003c\/a\u003e     \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/DSC_1917.jpg?v=1706219938\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/DSC_1917_100x100.jpg\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003ca class=\"MagicThumb\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/DSC_1917.jpg\" rel=\"lightbox\"\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003e\u003c\/span\u003e\u003c\/a\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWater Cooling\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eThere are four water-cooling bracket blocks, two on each side.\u003c\/li\u003e\n\u003cli\u003eTwo water cooling ports on each block.\u003c\/li\u003e\n\u003cli\u003eIllustration of linking all four half-water cooling blocks in series.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca class=\"MagicThumb\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/Tube-HP-85-50-1000_Watercooling.jpg\"\u003e\u003cimg height=\"48\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/Tube-HP-85-50-1000_Watercooling.jpg\" style=\"border: 1px solid black;\" width=\"64\"\u003e\u003c\/a\u003e    \u003ca class=\"MagicThumb\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/Tube-HP-85-50-1000_WC_Ports.jpg\"\u003e\u003cimg height=\"47\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/Tube-HP-85-50-1000_WC_Ports.jpg\" style=\"border: 1px solid black;\" width=\"71\"\u003e\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOption Water Cilller\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eMust have a water chiller while heating this tube, or it will cause damage to the flanges.\u003c\/li\u003e\n\u003cli\u003eA water chiller is required, but not included, please click to order at extra cost.\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv style=\"text-align: start;\"\u003e\u003ca href=\"KJ5000\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/CW5000DIfu2.1_100x100.jpg\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003c\/a\u003e\u003c\/div\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended\u003cbr\u003eOptional Tool \u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003ePlease use a torque wrench to make sure the equal forces to be applied to the bolts when installing the CF flange in MTI high-pressure furnace.\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"cftq-m14\" rel=\"noopener\" target=\"_blank\"\u003eHex Bit Socket M14 of Torque wrench for CF flange installation CFTQ-M14\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca class=\"MagicThumb\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/HexBitSocketSet.jpg\"\u003e\n\u003cdiv style=\"text-align: start;\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/HexBitSocketSet_100x100.jpg\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003c\/div\u003e\n\u003c\/a\u003e   \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e, \u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum pressure inside the tube\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003eHeating temperature\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. 1958 PSI  (13.5Mpa)    (140 Bar)\u003c\/td\u003e\n\u003ctd\u003e800°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. 1189 PSI  (8.2 Mpa)    (80 Bar)\u003c\/td\u003e\n\u003ctd\u003e900°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. 595  PSI  (4.1 Mpa)     (40 Bar)\u003c\/td\u003e\n\u003ctd\u003e1000°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. 362  PSI  (2.5 Mpa)     (25 Bar)\u003c\/td\u003e\n\u003ctd\u003e1100°C (for \u0026lt;1hr)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"MTI","offers":[{"title":"Default Title","offer_id":44984819056779,"sku":"TGH85D1000","price":0.0,"currency_code":"MYR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0716\/4405\/3643\/files\/TubeHP85501000Main_e1e6273a-9d77-4dc6-ba5f-fdfd6b1aee5a.jpg?v=1764850865","url":"https:\/\/mtimalaysia.com\/products\/tube-hp-85-50-1000","provider":"MTI Malaysia \u0026 Indonesia","version":"1.0","type":"link"}