{"product_id":"otf-1500x-vt-iii-pgep","title":"1500C Max Vertical Pyrolysis Furnace for Synthesis Nanoparticles - OTF-1500X-VT-III-PGEP","description":"\u003cp\u003eOTF-1500X-VT-III-PGEP is a multifunctional synthesis system designed for synthesizing various nanostructured oxides and composite-coating processes for nanomaterials. The instrument comprises three main modules: a gas atomizer, a 1500°C three-zone vertical tube furnace, and a collection device. The material fabrication involves approximately three steps: precursor atomization, heating, and nanoparticle collection. This system is highly advanced, allowing control over particle size, morphology, micro-nanostructure, etc., making it suitable for a wide range of applications including nano-material preparation and electrode material coating composites.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Features\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cul\u003e\n\u003cli\u003eEquipped with a two-fluid gas atomization device to atomize the liquid into liquid particles, which are then introduced into the tube furnace.\u003c\/li\u003e\n\u003cli\u003eVertical tube furnace with a maximum temperature of 1500°C.\u003c\/li\u003e\n\u003cli\u003eParticle powder collection: cyclone+ filter\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"9\"\u003eTube Furnace\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003eVoltage \u0026amp; Power\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eAC 208-240V, 3 phase, 50\/60Hz\u003c\/li\u003e\n\u003cli\u003e20KW\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermocouple\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eType S\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWorking Temperature\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e1400°C continuous\u003c\/li\u003e\n\u003cli\u003e1500°C Max. \u0026lt; 30 min\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating \/ Cooling Rate\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e≤10℃\/min (under 1400℃)\u003c\/li\u003e\n\u003cli\u003e≤5℃\/min (above 1400℃)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Zone\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e900mm (300mm*3)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Elements\u003c\/td\u003e\n\u003ctd\u003eSilicon Carbide\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Controller\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003ePID automatic control, 28 programmable segments for precise control of heating, cooling, and dwell times.\u003c\/li\u003e\n\u003cli\u003eBuilt-in over-temperature alarm and thermocouple disconnection alarm\u003c\/li\u003e\n\u003cli\u003e± 1 ºC temperature control at dwelling process\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessing Tube\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eThe high-quality fused quartz tube is included for operation @ 1200C.\u003c\/li\u003e\n\u003cli\u003e(I.D.: 21mm x OD: 25mm x 1200 mm length).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlanges \u0026amp; Fittings\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eUpper flange: KF50 for connecting the gas atomization device\u003c\/li\u003e\n\u003cli\u003eLower flange:\n\u003cul\u003e\n\u003cli\u003eKF25 for connecting the cyclone\u003c\/li\u003e\n\u003cli\u003eφ6.35mm hose adapter serves as an exhaust port, controlled by a stainless steel needle valve. A safety pressure relief valve is installed, automatically releasing pressure when the internal gas pressure reaches 0.02MPa.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAll flanges can be equipped with variable-diameter ring gaskets\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eAtomization System\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eTwo-Fluid Nozzle\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/OTF-1500X-VT-III-PGEP_twofluid.jpg?v=1711661813\" target=\"_blank\" rel=\"noopener\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/OTF-1500X-VT-III-PGEP_twofluid.jpg?v=1711661813\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eBy utilizing high-speed air, the liquid is crushed, reducing particle size, and enabling ejection of liquid with smaller particles and higher flow rates.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e316 stainless steel structure providing resistance to general corrosion\u003c\/li\u003e\n\u003cli\u003eEquipped with a set of vertically fixed flanges for the two-fluid atomization nozzle\u003c\/li\u003e\n\u003cli\u003eEccentrically adjustable (15°) flanges for the atomization nozzle\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeristaltic Pump\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eFlow Rate: 0.051 - 51 ml\/minute (adjustable)\u003c\/li\u003e\n\u003cli\u003eRotational Speed: 0.1 - 100 rpm (adjustable)\u003c\/li\u003e\n\u003cli\u003eDrawn Back Speed: 10 - 300 rpm\u003c\/li\u003e\n\u003cli\u003eDimensions: 160 * 300 * 170 mm (Length * Width * Height)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNanopowder Collection\u003c\/td\u003e\n\u003ctd\u003eCyclone + Filter\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eTwo sets of SS304 cyclone collectors with two stainless steel collection bins, each with a volume of 500ml.\u003c\/li\u003e\n\u003cli\u003eA filter (5um mesh) is installed at the outlet of the cyclone collector, capable of collecting finer particles with a size of up to ~2um.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh-pressure Atomizing and Auxiliary Gas Device\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003eAir compressor:\u003cbr\u003e(The two-fluid atomizing nozzle requires a certain flow rate and pressure of gas to atomize the liquid)\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePower: 1350W\u003c\/li\u003e\n\u003cli\u003eVolumetric Flow Rate: 0.11m3\/min\u003c\/li\u003e\n\u003cli\u003eWorking Pressure: 0.7Mpa\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eBlower:\u003cbr\u003e(To ensure that the atomized particles enter the heating furnace vertically along the furnace tube)\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVoltage: 220-240V\u003c\/li\u003e\n\u003cli\u003ePower: 0.18KW\u003c\/li\u003e\n\u003cli\u003eMax Flow Rate: 0.8m³\/min\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication Notes\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #ff0000;\"\u003eThe pressure inside the furnace tube must not exceed 0.02 MPa.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #ff0000;\"\u003eA relief valve must be installed on the gas source(high pressure).\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #ff0000;\"\u003eFor experiments involving sample heating, it is not recommended to close the exhaust valve and intake valve at the flange end of the furnace tube. If it is necessary to close the gas valve for sample heating, the pressure gauge reading must be monitored constantly. If the gas pressure reading exceeds 0.02 MPa, the exhaust valve must be opened immediately to\u003cstrong\u003e prevent accidents such as furnace tube rupture or flange detachment.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #ff0000;\"\u003eWe do not recommend customers use flammable, explosive, or toxic gases. If customers need to use such gases due to process requirements, they must take their own safety precautions and explosion prevention measures. MTI is not responsible for any issues related to the use of flammable, explosive, or toxic gases.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"MTI","offers":[{"title":"Default Title","offer_id":44985204015243,"sku":"OTF-1500X-VT-III-PGEP","price":0.0,"currency_code":"MYR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0716\/4405\/3643\/files\/OTF-1500X-VT-III-PGEP_main_fa0139c5-5f96-42a2-ae84-8be8a2d128be.jpg?v=1764855304","url":"https:\/\/mtimalaysia.com\/products\/otf-1500x-vt-iii-pgep","provider":"MTI Malaysia \u0026 Indonesia","version":"1.0","type":"link"}