{"product_id":"otf-1200x-iv-s","title":"Four Zones 1200oC Tube Furnace w\/ Temperature Controllers for 1 or 2\" Tube - OTF-1200X-IV-S","description":"OTF-1200X-IV-S is the smallest 1100 o C Four- Zone split tube furnace with a separate temperature control console. Such a four-zone furnace can create a step thermal gradient or uniform temperature zone up to 10\" long by adjusting the four zones' temperature. The furnace can accept 1-2” OD processing tube (with min. 1000mmL). Four digital temperature controller is built in a separable unit .  It is an excellent furnace for various CVD, and PVD applications.\u003cbr\u003e\u003cbr\u003e\u003ctable border=\"1\" cellpadding=\"1\" cellspacing=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003eFurnace structure\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/OTF1200XIVSD2.jpg\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/OTF-1200X-IV-S-D2_100x100.png\"\u003e\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cdiv\u003eDouble layer steel case with air cooling keeps the furnace surface temperature lower than 60°C.\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003eEnergy-saving high purity fibrous alumina insulation.\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003eHeating Element:1300C grade Fe-Cr-Al Alloy doped by Mo\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e400mm long heating chamber with built-in four high-quality thermal couples. \u003c\/li\u003e\n\u003cli\u003eThe furnace heating module can be positioned horizontally or vertically as shown in the images below \u003cstrong\u003e\u003cem\u003e(Note: customers are responsible for DIY the support frame\/bracket in order to maintain its vertical position)\u003c\/em\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003e\n\u003cbr\u003ePower \u0026amp; Voltage\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eAC 110V Single Phase, 50\/60 Hz, 30 A\u003c\/strong\u003e\u003cbr\u003e(Use a \u003ca href=\"TF-220110-5000-LD\" rel=\"noopener\" target=\"_blank\"\u003e5000W transformer\u003c\/a\u003e for 208-240VAC).\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e3 KW Max. (a 32A circuit breaker is installed)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003eA powder cord is included without a plug \u003cbr\u003e\u003cem\u003e\u003cstrong\u003e(Never plug the equipment into a NEMA 5-15\/20R wall outlet)\u003c\/strong\u003e\u003c\/em\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003eMax. Temperature\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cli\u003eMax. working temperature: 1200\u003csup\u003eo\u003c\/sup\u003eC (\u0026lt;1 Hour, without vacuum)\u003c\/li\u003e\n\u003cli\u003eContinuous Working Temperature 1100\u003csup\u003eo\u003c\/sup\u003eC\u003c\/li\u003e\n\u003cli\u003eMax. Heating Rate: ≤ 20\u003csup\u003eo\u003c\/sup\u003eC \/min\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003e\n\u003cbr\u003e\u003cbr\u003eHeating Zones\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cdiv\u003eFour heating zones with independent temperature control\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003eEach heating zone length 100 mm\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003eTotal heating zone length: 400mm (15.75\" in total)\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003eMax. Constant temperature zone length 250mm, +\/- 1°C (if 4 zones are heated to the same temperature)\u003c\/li\u003e\n\u003cli\u003eMax. temperature difference between adjacent zones is 200°C.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003e\n\u003cbr\u003eTemperature Controllers\u003cbr\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cli\u003eFour digital temperature controllers are included and control 4 heating zone independently, \u003c\/li\u003e\n\u003cli\u003ePID automatic control for heating rate, cooling rate, and dwell time up to 30 segments\u003c\/li\u003e\n\u003cli\u003eBuilt-in overheating \u0026amp; broken thermocouple protection.\u003c\/li\u003e\n\u003cli\u003e+\/- 1 ºC temperature accuracy.\u003c\/li\u003e\n\u003cli\u003eFour K-type thermocouples (one for each zone).\u003c\/li\u003e\n\u003cli\u003eRS485 communications port\u003c\/li\u003e\n\u003cli\u003eSoftware and remote PC operation are available at an extra cost.\u003c\/li\u003e\n\u003cli\u003eTouch screen controller is available at an extra cost\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cbr\u003eOptional Processing Tube \u0026amp; \u003cbr\u003eVacuum flange\u003cbr\u003e(Optional)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003e\n\u003cdiv\u003eThe furnace can accommodate \u0026lt;= 1\" Dia. or 2\" x 40\" long quartz tube with vacuum flanges and thermal blocks. These accessories are not included in the standard package, please click the pictures below to order.\u003cbr\u003e\u003ca href=\"https:\/\/mtixtl.com\/search?q=Quartz+Tube\u0026amp;options%5Bprefix%5D=last\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/thumb_quartz-tube-400w_50x50.jpg?v=1706297129\"\u003e\u003c\/a\u003e     \u003ca href=\"https:\/\/mtixtl.com\/search?q=Sealing+flanges+for+%3C+%3D+1%22+%288+-+25.4mm%29+O.D+tube\u0026amp;options%5Bprefix%5D=last\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg alt=\"Vacuum Components for Tube Furnaces Flanges, ( Fittings, Valves \u0026amp; Gauges )\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/compo_100x100.jpg?v=1706297902\"\u003e\u003c\/a\u003e      \u003ca href=\"f-t-block-18\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/tube_block_catagory_100x100.jpg?v=1706297753\"\u003e\u003c\/a\u003e\u003ca href=\"F-T-block-18\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"http:\/\/www.mtixtl.com\/aluminafoamblock18mmdiameteronepairfor1tubefurnace-eq-f-t-block-18.aspx\"\u003e \u003c\/a\u003e\u003cspan lang=\"EN-US\"\u003e\u003cbr\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003e\n\u003cdiv\u003eThermal Block Placement\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/Quartz_tube_block.jpg?v=1706132457\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/Quartz_tube_block_100x100.jpg\"\u003e\u003c\/a\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompliance\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eCE Certified\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eNRTL or CSA certification is available upon request\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptions (click picture to order at extra cost)\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"cvm211ld\" rel=\"noopener\" target=\"_blank\"\u003ePlease click Pic.1\u003c\/a\u003e to\u003ca href=\"cvm211ld\" rel=\"noopener\" target=\"_blank\"\u003e order a digital vacuum gauge\u003c\/a\u003e\u003ca href=\"index.asp?PageAction=VIEWPROD\u0026amp;ProdID=1442\"\u003e\u003cbr\u003e\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003eFor CVD application, suggest you choose a rotary pump with cold trap ( by click Pic,2)\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"pv-hvs-ld\" rel=\"noopener\" target=\"_blank\"\u003eIf need a high vacuum \u0026gt; 10-5 torr, please click Pic. 2 to order a turbo pump\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\n\u003ca href=\"cvm211ld\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/thumb_vg-tube3_50x50.jpg?v=1706298410\"\u003e\u003c\/a\u003e Pic.1 \u003ca href=\"FYP\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg alt=\"\" border=\"0\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/EQ-FYP-Pump.1_50x50.jpg\" title=\"\"\u003e\u003c\/a\u003ePic. 2 \u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cbr\u003eOperation Instruction\u003cbr\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eThe tube furnaces with quartz\/mullite tubes are designed for use under vacuum and low pressure \u0026lt;0.2 bars\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003eA\u003c\/span\u003e\u003cem\u003e\u003cstrong\u003e\u003cem\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003e\u003cstrong\u003ettention\u003c\/strong\u003e: A two-stage pressure regulator must be installed on the gas cylinder to limit the pressure to below 3 PSI for safe\u003c\/span\u003e operation.\u003c\/em\u003e \u003ca href=\"cga580\" rel=\"noopener\" target=\"_blank\"\u003eClick here to learn the installation of a gas regulator.\u003c\/a\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003eVacuum pressures may only be safely used up to 1000°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"MTI","offers":[{"title":"Default Title","offer_id":44985150210187,"sku":"OTF1200XIVS","price":0.0,"currency_code":"MYR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0716\/4405\/3643\/files\/OTF1200XIVS.1.1.2_cca0a4e7-b1fa-49ea-822e-95f5fc5c3965.jpg?v=1764854645","url":"https:\/\/mtimalaysia.com\/products\/otf-1200x-iv-s","provider":"MTI Malaysia \u0026 Indonesia","version":"1.0","type":"link"}