{"product_id":"otf-1200x-iii-80-f3lv","title":"Three Zone Quartz Tube Furnace (80mm Dia, 1200C Max) with 3 Channel Gas Mixer, Vacuum Pump, \u0026 Anti-Corrosive Vacuum Gauge - OTF-1200X-III-80-F3LV","description":"OTF-1200X-III-80-F3LV is a splittable three zones Tube furnace with a mechanical vacuum pump \u0026amp; digital vacuum gauge and three channels gas flowing system, which can achieve vacuum up to 10 -2 torr and mix 1-3 types of gases for CVD or diffusion. This furnace system also includes an anti-corrosive Pirani Capacitance Diaphragm Gauge to enable vacuum measurements with aggressive gases. SPECIFICATIONS Furnace Construction Double-layer steel casing with air cooling High-purity alumina fiber insulation for max. energy saving Splittable cover for easy tube replacement Power Consumption 5 KW Input Voltage AC 208-240V Single Phase, 50 or 60 Hz Maximum Temperature 1200 o C ContinuousTemperature 1100 o C Maximum Heating Rate \u0026lt;= 20 o C \/min Heating Zone Length Three zones: (880mm, 35\" in total) Zone 1: 220mm (8.6\" ) Zone 2: 440mm (17.3\") Zone 3: 220 mm (8.6\") Constant Temperature Zone If three zones are set at the same temperature, the constant temperature zone is 25\" (625 mm) long with a temperature discrepancy of +\/- 1 o C. If using only one zone (center zone), the constant temperature zone is 4.3\" (110 mm) long with a temperature discrepancy of +\/- 1 o C. Temperature Accuracy +\/- 1 o C Heating Elements Fe-Cr-Al Alloy doped by Mo Temperature Controller Three precision temperature controllers to control three zones separately. PID automatic control with 30 programmable segments for precise control of heating rate, cooling rate, and dwell time. Built-in overheating \u0026amp; broken thermocouple protection. Over temperature protection and alarm allows for operation without attendant(s). +\/- 1 ºC temperature accuracy. RS485 Communications Port. Optional: The furnace may be operated by PC by installing three control modules. Please order the MTS-02 control modules at an extra cost. The new version of PC module is now compatible with Lab View 05\/08\/2014 If you order the PC control module together with the furnace, we will install and test it before shipping. We recommend you to order a computer laptop from us to avoid software installation problems. For more information please click here. Quartz Tube\u0026amp; Sealing Flanges 80 mm O.D x 72 mm ID. x 1400 mm fused quartz tube included. Vacuum flanges with valves and pressure gauges are included. The thermal block must be placed inside the tube as in the drawing below click here to choose a crucible Vacuum Sensor \u0026amp; Display Corrosion-proof Capacitance Diaphragm Gauge with ceramic coated sensor head specially designed for vacuum measurements with the presence of corrosive gases. Gauge is installed on the vacuum flange (right side) of the tube furnace and provides a wide measure range (10^ -5 ~ 1000 torr). Optional: click the pic-below- right to order the Constant temperature control module. Sliding Flange with Sample Holder Slide for transferring sample (manually operated) is available as an option at $1900 extra cost (please refer to pictures below). Please click here to order 3\"wafer quartz boat to anneal 3\" wafer Vacuum Sealing Flanges Two stainless steel flanges with both vacuum gauge and valves included. Min. vacuum pressure achieved by the mechanical pump is 5.5 m-torr. ( 5.5x10^ -3 torr). The pressure can reach 10^ -5 torr by using a mechanical + molecular pump. The leaking rate is \u0026lt; 5 m-torr \/ min. and stable vacuum pressure after 24 hours is \u0026lt; 2 torr. Click the picture below to get a details chart and data measured by CE certified vacuum meter: (For a whole 24 hours curve display, the time segment through 08:00:00~21:10:00 in X axis is passed over in the chart, therefore, steep variety in there) Oxygen Monitoring An Oxygen Sensor can be used to monitor the oxygen level of gas(es) used in CVD systems for preventing or reducing oxidation. Please click the picture below to learn more: Vacuum Pump 120 L\/m Rotary Vane Vacuum Pump is included with max. vacuum pressure of 10^ -2 torr. Stainless steel hose tube is included for connecting to the tube furnace. Option: For precise control of the vacuum pressure, we recommend you choose our turn-key solution VPC-MV. This is a vacuum pressure regulating system with a motorized valve and gauge. It controls pressure range from 10^-6 torr ~ 760 torr. Gas Flow Meter and Pressure Meter Three gas flow meters (4% accuracy FS) are installed inside the mobile case to enable monitoring of gas flowing rates (three different kinds of gases in total). Compact direct read flow meter, 10-100 cc\/min. Compact direct read flow meter, 16-160 cc\/min. Compact direct read flow meter, 25-250 cc\/min. Four pressure meters are installed inside the mobile cart which is able to monitor three types of flowing gas pressure as well as the pressure of the mixing tank. Valves Four stainless steel valves are installed in the side panel of the mobile cart to control the mixing of three inlet gases separately Laptop, software \u0026amp; WiFi Control (Optional) Brand new laptop with Microsoft Windows 10 and Microsoft Office 2013 (30 days free trial) for immediate use. Labview-Based Temperature Control System ( MTS01 ) enables users to edit temperature profiles, manage heat-treatment recipes, and record and plot data for MTI furnaces. Compliance CE Certified UL \/ MET \/ CSA Certification is available upon request, additional charges will apply Application Notes Click here to learn about the installation of a gas regulator Please click here to see our typical temperature profile calibration result at various temperatures. From 7\/15\/08, MTI calibrates each furnace by NIST certificated Omega CL3515R precision Temperature calibrator , and pre-set temperature off (SC value) in the controller before shipping. In order to obtain an accurate temperature inside the tube furnace, you need to calibrate the temperature by yourselves. Please click here to learn how. How to set up a ceramic tube and vacuum flange for MTI Tube Furnace. Tube furnaces with alumina tubes are designed for using under vacuum and low pressure \u0026lt; 0.2 bar \/ 3 psi \/ 0.02 MPa The flow rate for gases should be limited to \u0026lt; 200 SCCM (or 200 ml\/min) for reducing thermal shocks to the tube Attention: A two-stage pressure regulator must be installed on gas cylinder to limit the pressure to below 3 PSI for safe operation. Click here to learn the installation of a gas regulator. Vacuum limit definition for all quartz tube furnaces: * Vacuum pressures may only be safely used up to 1000°C\u003cbr\u003e\u003cbr\u003e\u003ctable border=\"1\" cellpadding=\"1\" cellspacing=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace Construction\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eDouble-layer steel casing with air cooling\u003c\/li\u003e\n\u003cli\u003eHigh-purity alumina fiber insulation for max. energy saving\u003c\/li\u003e\n\u003cli\u003eSplittable cover for easy tube replacement\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePower Consumption\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e5 KW\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eInput Voltage\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eAC 208-240V Single Phase, 50 or 60 Hz \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMaximum Temperature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e1200\u003csup\u003eo\u003c\/sup\u003eC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eContinuousTemperature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e1100\u003csup\u003eo\u003c\/sup\u003eC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMaximum Heating Rate\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u0026lt;= 20 \u003csup\u003eo\u003c\/sup\u003eC \/min\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eHeating Zone Length\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eThree zones: (880mm, 35\" in total)\u003c\/li\u003e\n\u003cul\u003e\n\u003cli\u003eZone 1: 220mm (8.6\" )\u003c\/li\u003e\n\u003cli\u003eZone 2: 440mm (17.3\")\u003c\/li\u003e\n\u003cli\u003eZone 3: 220 mm (8.6\")\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eConstant Temperature Zone\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eIf three zones are set at the same temperature, the constant temperature zone is 25\" (625 mm) long with a temperature discrepancy of +\/- 1\u003csup\u003eo\u003c\/sup\u003eC.\u003c\/li\u003e\n\u003cli\u003eIf using only one zone (center zone), the constant temperature zone is 4.3\" (110 mm) long with a temperature discrepancy of +\/- 1\u003csup\u003eo\u003c\/sup\u003eC.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eTemperature Accuracy\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e+\/- 1\u003csup\u003eo\u003c\/sup\u003eC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eHeating Elements\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eFe-Cr-Al Alloy doped by Mo\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eTemperature Controller\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eThree precision temperature controllers to control three zones separately.\u003c\/li\u003e\n\u003cli\u003ePID automatic control with 30 programmable segments for precise control of heating rate, cooling rate, and dwell time.\u003c\/li\u003e\n\u003cli\u003eBuilt-in overheating \u0026amp; broken thermocouple protection.\u003c\/li\u003e\n\u003cli\u003eOver temperature protection and alarm allows for operation without attendant(s).\u003c\/li\u003e\n\u003cli\u003e+\/- 1 ºC temperature accuracy.\u003c\/li\u003e\n\u003cli\u003eRS485 Communications Port.\u003c\/li\u003e\n\u003cli\u003eOptional:\u003c\/li\u003e\n\u003cul\u003e\n\u003cli\u003eThe furnace may be operated by PC by installing three control modules. Please order the MTS-02 control modules at an extra cost. \u003c\/li\u003e\n\u003cli style=\"color: rgb(255, 42, 0);\"\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003e\u003cstrong\u003eThe new version of PC module is now compatible with Lab View 05\/08\/2014\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003eIf you order the PC control module together with the furnace, we will install and test it before shipping. We recommend you to order a computer laptop from us to avoid software installation problems. For more information please \u003ca href=\"https:\/\/mtixtl.com\/blogs\/knowledge-base\/mti-temperature-control-software-for-laboratory-furnace?_pos=2\u0026amp;_sid=3c4d4d1d5\u0026amp;_ss=r\" target=\"_blank\"\u003eclick here.\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/Temperature_Control.jpg?v=1706135240\" target=\"_blank\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/Temperature_Control_50x50.jpg\"\u003e\u003c\/a\u003e  \u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003eQuartz Tube\u0026amp; Sealing Flanges\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003ca href=\"qztube-80d-1400\" rel=\"noopener\" target=\"_blank\"\u003e80 mm O.D x 72 mm ID. x 1400 mm fused quartz tube\u003c\/a\u003e\u003ca href=\"http:\/\/mtixtl.com\/quartztube80odx72idx1400lmm314dx55fordiytubefurnace-eqquartz-tube-80d-1400.aspx\"\u003e\u003c\/a\u003e included.\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003eVacuum flanges with valves and pressure gauges are included. \u003c\/li\u003e\n\u003cli\u003eThe thermal block must be placed inside the tube as in the drawing below \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv style=\"text-align: start;\"\u003e       \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/Quartz_tube_block.jpg?v=1706132457\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/Quartz_tube_block_50x50.jpg\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003c\/a\u003e    \u003cspan style=\"font-size: 0.875rem;\"\u003e\u003ca href=\"https:\/\/mtixtl.com\/search?q=Quartz+Boat\u0026amp;options%5Bprefix%5D=last\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg alt=\"\" height=\"43\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/thumb_quartz_crucible.jpg\" width=\"77\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003ca href=\"https:\/\/mtixtl.com\/search?q=Quartz+Boat\u0026amp;options%5Bprefix%5D=last\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003e click here to choose a crucible\u003c\/span\u003e\u003c\/a\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVacuum Sensor \u0026amp; Display\u003cbr\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"pgc554ld\" rel=\"noopener\" target=\"_blank\"\u003eCorrosion-proof Capacitance Diaphragm Gauge\u003c\/a\u003e with ceramic coated sensor head specially designed for vacuum measurements with the presence of corrosive gases.\u003c\/li\u003e\n\u003cli\u003eGauge is installed on the vacuum flange (right side) of the tube furnace and provides a wide measure range (10^\u003csup\u003e-5\u003c\/sup\u003e ~ 1000 torr).\u003c\/li\u003e\n\u003cli\u003eOptional: click the pic-below- right to order the \u003ca href=\"https:\/\/mtixtl.com\/search?q=Vacuum+%26+Pressure+Gauges+and+Controller\u0026amp;options%5Bprefix%5D=last\" rel=\"noopener\" target=\"_blank\"\u003eConstant temperature control module.\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\n\u003cdiv style=\"text-align: start;\"\u003e\n\u003ca href=\"pgc554ld\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg alt=\"Capacitance Diaphragm Gauge with Power Supply, Up to 3.8E-5 Torr - PGC-554-LD\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/PGC554LD_50x50.jpg?v=1739407469\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003c\/a\u003e     \u003cstrong\u003e\u003cstrong\u003e\u003ca href=\"kjt2v\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg border=\"0\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/Pressurecontroller_50x50.jpg\" style=\"margin-bottom: 16px; float: none;\" title=\"\"\u003e\u003c\/a\u003e\u003ca href=\"KJT-2V\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/strong\u003e\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eSliding Flange with Sample Holder\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cdiv\u003eSlide for transferring sample (manually operated) is available as an option at $1900 extra cost (please refer to pictures below).\u003cbr\u003ePlease click here to order 3\"wafer quartz boat to anneal 3\" wafer \u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/sample-transformer.jpg?v=1706297252\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/thumb_sample-transformer_50x50.jpg?v=1706297252\" style=\"float: none;\"\u003e\u003c\/a\u003e     \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/wafer1.jpg?v=1706307033\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/Thumb_Wafer1_50x50.jpg\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/OTF1200x-3CLV_Leaking_Rate_Chart_and_Data_eb6671cc-a592-4fc4-bb4e-4375aa0ce2b0.xls?v=1739991804\" rel=\"noopener\" target=\"_blank\"\u003eVacuum Sealing Flanges\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/mti-kjgroup.com\/ProductImages\/furnace\/vacuum-system\/OTF1200x-3CLV%20Leaking%20Rate%20Chart%20and%20Data.xls\"\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/OTF1200x-3CLV_Leaking_Rate_Chart_and_Data_eb6671cc-a592-4fc4-bb4e-4375aa0ce2b0.xls?v=1739991804\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003c\/div\u003e\n\u003c\/a\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eTwo stainless steel flanges with both vacuum gauge and valves included.\u003c\/li\u003e\n\u003cli\u003eMin. vacuum pressure achieved by the mechanical pump is 5.5 m-torr. ( 5.5x10^\u003csup\u003e-3\u003c\/sup\u003e torr). The pressure can reach 10^\u003csup\u003e-5\u003c\/sup\u003e torr by using a mechanical + molecular pump.\u003c\/li\u003e\n\u003cli\u003eThe leaking rate is \u0026lt; 5 m-torr \/ min. and stable vacuum pressure after 24 hours is \u0026lt; 2 torr.\u003c\/li\u003e\n\u003cli\u003eClick the picture below to get a details chart and data measured by CE certified vacuum meter: \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003e(For a whole 24 hours curve display, the time segment through 08:00:00~21:10:00 in X axis is passed over in the chart, therefore, steep variety in there)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOxygen Monitoring\u003cbr\u003e\u003c\/p\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003ca href=\"w1000\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/EQW1000FT_100x100.jpg\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003c\/a\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eAn Oxygen Sensor can be used to monitor the oxygen level of gas(es) used in CVD systems for preventing or reducing oxidation. Please click the picture below to learn more:\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eVacuum Pump\u003cbr\u003e\u003c\/p\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003ca href=\"FYP\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/EQ-FYP-Pump_50x50.jpg\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003c\/a\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e120 L\/m Rotary Vane Vacuum Pump is included with max. vacuum pressure of 10^\u003csup\u003e-2\u003c\/sup\u003etorr. Stainless steel hose tube is included for connecting to the tube furnace.\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eOption: For precise control of the vacuum pressure, we recommend you choose our turn-key solution \u003ca href=\"vpc-mv-ld\" rel=\"noopener\" target=\"_blank\"\u003eVPC-MV.\u003c\/a\u003e This is a vacuum pressure regulating system with a motorized valve and gauge. It controls pressure range from 10^-6 torr ~ 760 torr.\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003ca href=\"vpc-mv-ld\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/Precisionvacuumpressureregulatingsystem_100x100.jpg\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003c\/a\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eGas Flow Meter and Pressure Meter\u003c\/p\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003ca href=\"OTF-1200X-III-80-F3LV\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg alt=\"New Version front panel\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/VGS3F_50x50.jpg\" style=\"float: none;\"\u003e\u003c\/a\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"FM100\" target=\"_blank\"\u003e\u003cstrong\u003eThree gas flow meters (4% accuracy FS)\u003c\/strong\u003e\u003c\/a\u003e are installed inside the mobile case to enable monitoring of gas flowing rates (three different kinds of gases in total).\u003c\/li\u003e\n\u003cul\u003e\n\u003cli\u003e Compact direct read flow meter, 10-100 cc\/min.\u003c\/li\u003e\n\u003cli\u003e Compact direct read flow meter, 16-160 cc\/min.\u003c\/li\u003e\n\u003cli\u003e Compact direct read flow meter, 25-250 cc\/min.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFour pressure meters\u003c\/strong\u003e are installed inside the mobile cart which is able to monitor three types of flowing gas pressure as well as the pressure of the mixing tank.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eValves\u003c\/td\u003e\n\u003ctd\u003eFour stainless steel valves are installed in the side panel of the mobile cart to control the mixing of three inlet gases separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eLaptop, software \u0026amp; WiFi Control (Optional)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/wifi_GSL_OTF_bd021bfe-909d-4c51-9795-160125f3382a.jpg?v=1736202700\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/wifi_GSL_OTF_50x50.jpg?v=1706136855\"\u003e\u003c\/a\u003e      \u003ca href=\"https:\/\/mtixtl.com\/products\/MTS01\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/temperaturecontrolsystem1_fe5a229c-8bca-45aa-abbe-b5b938de0d58_50x50.jpg?v=1736202779\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eBrand new laptop with Microsoft Windows 10 and Microsoft Office 2013 (30 days free trial) for immediate use.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cb\u003e\u003ci\u003eLabview-Based Temperature Control System (\u003ca href=\"MTS01\" target=\"_blank\"\u003eMTS01\u003c\/a\u003e)\u003c\/i\u003e\u003c\/b\u003e\u003cb\u003e \u003c\/b\u003eenables users to edit temperature profiles, manage heat-treatment recipes, and record and plot data for MTI furnaces.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCompliance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cspan\u003eCE Certified\u003c\/span\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eUL \/ MET \/ CSA Certification is available upon request, \u003cstrong\u003eadditional charges will apply\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan\u003eApplication Notes\u003c\/span\u003e\u003cbr\u003e\u003ca href=\"http:\/\/www.mtixtl.com\/twostagebrass0-100psianalyticalcylinderregulatorcga-580withneedlevalve-fa-y12244d580.aspx\"\u003e\u003cbr\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/EQGRCGA580_50x50.jpg?v=1706220710\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan face=\"arial, helvetica, sans-serif\" size=\"2\"\u003eClick here to learn\u003c\/span\u003e\u003cspan face=\"arial, helvetica, sans-serif\" size=\"2\"\u003e about the installation of a gas regulator\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/a\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003ePlease click \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/Cal-OTF1200-3.pdf?v=1739990375\" target=\"_blank\"\u003ehere\u003c\/a\u003e to see our typical temperature profile calibration result at various temperatures.\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFrom 7\/15\/08, MTI calibrates each furnace by \u003ca href=\"https:\/\/mtixtl.com\/products\/tc-calibrator-ld\" target=\"_blank\"\u003eNIST certificated Omega CL3515R precision Temperature calibrator\u003c\/a\u003e, and pre-set temperature off (SC value) in the controller before shipping.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/How-calibrate_8.doc?v=1739555010\" target=\"_blank\"\u003e\u003cspan\u003eIn order to obtain an accurate temperature inside the tube furnace, you need to calibrate the temperature by yourselves. Please click here to learn how.\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/How-to-tube_flange_1.doc?v=1739578848\" target=\"_blank\"\u003e\u003cspan\u003eHow to set up a ceramic tube and vacuum flange for MTI Tube Furnace.\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"color: rgb(255, 42, 0);\"\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003eTube furnaces with alumina tubes are designed for using under vacuum and low pressure \u0026lt; 0.2 bar \/ 3 psi \/ 0.02 MPa\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"color: rgb(255, 42, 0);\"\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003eThe flow rate for gases should be limited to \u0026lt; 200 SCCM (or 200 ml\/min) for reducing thermal shocks to the tube\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cspan face=\"arial, helvetica, sans-serif\" size=\"2\"\u003e\u003cem\u003e\u003cstrong\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003eAttention: A two-stage pressure regulator must be installed on gas cylinder to limit the pressure to below 3 PSI for safe operation.\u003c\/span\u003e \u003ca href=\"https:\/\/mtixtl.com\/products\/cga580\" target=\"_blank\"\u003eClick here to learn the installation of a gas regulator.\u003c\/a\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"color: rgb(255, 42, 0);\"\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003eVacuum limit definition for all quartz tube furnaces: * Vacuum pressures may only be safely used up to 1000°C\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"MTI","offers":[{"title":"Default Title","offer_id":44985146966155,"sku":"OTF-1200X-III-80-F3LV","price":0.0,"currency_code":"MYR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0716\/4405\/3643\/files\/OTF-1200X-III-80-F3LV.jpg?v=1764854624","url":"https:\/\/mtimalaysia.com\/products\/otf-1200x-iii-80-f3lv","provider":"MTI Malaysia \u0026 Indonesia","version":"1.0","type":"link"}