{"product_id":"ksl1700xh2","title":"1650°C Max. High Temperature Hydrogen Atmosphere Box Furnace, (8 x 8 x 8\") - KSL-1700X-H2","description":"\u003cp\u003eKSL1700X-H2 is designed for material synthesis under dry hydrogen up to 1650ºC. The furnace consists of high-quality alumina fiber bricks and Mo alloy heating elements with a heating chamber of 8\" x 8\" x 8\", as well as a vacuum-sealed steel case with a water cooling jacket and an automatic H2 burning system. It is an ideal tool for preparing new materials that require a reducing atmosphere, such as phosphorous and Ti alloy.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSPECIFICATIONS \u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003eFurnace Structure\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cdiv\u003eDouble-layer stainless steel structure for maximum vacuum and safety\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003eWater cooling front door and air cooling shell\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003eBuilt-in pressure gauge, vacuum valves, and two gas float meters\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003eBuilt-in H2 burning control system - if the controller detects no flame in the burner, the gas delivery valve will be shut down automatically\u003c\/div\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003eHeated Chamber\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv style=\"text-align: start;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/KSL-1700X-H2_Door_Block.png\"\u003e\u003cspan style=\"color: #1f2124;\"\u003e\u003cspan style=\"color: #1f2124;\"\u003e\u003cspan style=\"color: #1f2124;\"\u003e\u003cspan style=\"color: #1f2124;\"\u003e\u003cspan style=\"color: #1f2124;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/KSL-1700X-H2_Door_Block_100x100.png\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul type=\"disc\"\u003e\n\u003cli\u003eVolume: 200 x 200 x 200 mm (8 x 8 x 8 inch), 8 Liter\u003c\/li\u003e\n\u003cli\u003eSample Load Capacity: 100kg Max.\u003c\/li\u003e\n\u003cli\u003eEnergy-saving 1800 grade fibrous alumina insulation\u003c\/li\u003e\n\u003cli\u003eHigh purity Al2O3 coating\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #ff0000;\"\u003eWarning: One Al2O3 fibrous door block is included. You must place the door block in the front of the chamber to block heat radiation, otherwise, may damage the sealing ring at high temperature and cause hydrogen gas leaking\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePower\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eAC 208 - 240V single phase (50\/60 Hz)\u003c\/li\u003e\n\u003cli\u003e9 KW\u003c\/li\u003e\n\u003cli\u003e50 Amp air breaker is required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eThermal\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eContinuous 1600°C\u003c\/li\u003e\n\u003cli\u003eMax. 1650°C (\u0026lt; 60min)\u003c\/li\u003e\n\u003cli\u003eAccuracy: +\/- 1°C\u003c\/li\u003e\n\u003cli\u003eHeating Rate:\n\u003cul\u003e\n\u003cli\u003e5°C\/min (\u003cspan\u003e≤\u003c\/span\u003e1200°C)\u003c\/li\u003e\n\u003cli\u003e2°C\/min (\u003cspan\u003e1200°C to1\u003c\/span\u003e600°C)\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eThermocouple\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003eB type (control thermocouple and secondary alarm thermocouple)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eTemperature Controller\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan data-end=\"58\" data-start=\"0\"\u003eEurotherm Temperature Controller\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli data-end=\"58\" data-start=\"0\"\u003e30 Segments\u003c\/li\u003e\n\u003cli data-end=\"137\" data-start=\"100\"\u003eTemperature Control Accuracy ± 1 °C\u003c\/li\u003e\n\u003cli data-end=\"172\" data-start=\"140\"\u003eTemperature Stability ± 0.1 °C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eFeatures\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp class=\"\" data-end=\"195\" data-start=\"174\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cspan data-end=\"193\" data-start=\"174\"\u003eAlarm Functions\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli data-end=\"222\" data-start=\"198\"\u003eOver-Temperature Alarm\u003c\/li\u003e\n\u003cli data-end=\"242\" data-start=\"225\"\u003eDeviation Alarm\u003c\/li\u003e\n\u003cli data-end=\"271\" data-start=\"245\"\u003eThermocouple-Break Alarm\u003c\/li\u003e\n\u003cli data-end=\"271\" data-start=\"245\"\u003eFurnace Chamber Pressure Alarm\u003c\/li\u003e\n\u003cli data-end=\"178\" data-start=\"151\"\u003eWater-Chiller Alerts:\n\u003cul\u003e\n\u003cli data-end=\"178\" data-start=\"151\"\u003eLow-Water-Level Alarm\u003c\/li\u003e\n\u003cli\u003eFlow-Restriction Alarm\u003c\/li\u003e\n\u003cli\u003ePipeline Overpressure Alarm\u003c\/li\u003e\n\u003cli\u003eHigh-Temperature Warning\u003c\/li\u003e\n\u003cli\u003ePrompt to Activate Water Cooling Before Opening the Furnace\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"\" data-end=\"298\" data-start=\"273\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cspan data-end=\"296\" data-start=\"273\"\u003eProtection Features\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli data-end=\"325\" data-start=\"301\"\u003eOvercurrent Protection\u003c\/li\u003e\n\u003cli data-end=\"352\" data-start=\"328\"\u003eOvervoltage Protection\u003c\/li\u003e\n\u003cli data-end=\"375\" data-start=\"355\"\u003eLeakage Protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"\" data-end=\"38\" data-start=\"0\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cspan data-end=\"38\" data-start=\"0\"\u003eAutomatic Furnace-Chamber Cleaning\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe vacuum pump and the gas-inlet system switch automatically, number of cleaning cycles is programmable\u003c\/li\u003e\n\u003cli\u003eManual Mode available\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"\" data-end=\"36\" data-start=\"0\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cspan data-end=\"36\" data-start=\"0\"\u003eConstant-Pressure Sintering Mode\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli data-end=\"287\" data-start=\"40\"\u003eAutomatically regulate the intake and exhaust flow rates to maintain a slight positive pressure inside the furnace throughout the heating cycle.\u003c\/li\u003e\n\u003cli data-end=\"339\" data-start=\"290\"\u003eConstant-pressure range: 105 000 Pa – 115 000 Pa.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan style=\"text-decoration: underline;\"\u003eDual Explosion-Proof Settings (Pressure Control)\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAn electronic pressure transmitter is used to monitor exhaust pressure. When the chamber pressure exceeds the preset exhaust-pressure setpoint, the exhaust valve opens to accelerate venting.\u003c\/li\u003e\n\u003cli\u003eA mechanical, explosion-proof relief valve is mounted at the top of the furnace chamber; it is set to open at 0.04 MPa\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"\" data-end=\"404\" data-start=\"377\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cspan data-end=\"402\" data-start=\"377\"\u003eElectrical Components\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli data-end=\"528\" data-start=\"407\"\u003eAll Electrical Components, Cables, and Cold-Pressed Terminals Use ABB Products\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eData Acquisition and Recording\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eTemperature-curve data acquisition and logging\u003c\/li\u003e\n\u003cli\u003ePressure-variation-curve data acquisition and logging\u003c\/li\u003e\n\u003cli\u003eAll collected data is automatically saved to the local hard drive\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eConnectivity\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eStandard Ethernet port\u003c\/li\u003e\n\u003cli\u003eSupports LAN and Internet connection for remote control and monitoring\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eHeating Elements\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cspan\u003eMo Coil\u003c\/span\u003e\u003cbr\u003e\u003ca href=\"k1700h2he\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/KSL1700X-H2_HE_50x50.jpg\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003eMoSi2\u003ca href=\"hel1800t-30360\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/EQHEL1800T.3_50x50.jpg?v=1706220709\" style=\"float: none; display: block; margin-left: auto; margin-right: auto;\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e6 sets of Mo coils heating elements are built-in and replaceable \u003c\/li\u003e\n\u003cli\u003eThe heating element of the Mo coil is consumable parts which should be ordered separately if extra is required. (click the pictures left to order spare)\u003c\/li\u003e\n\u003cli\u003eThe heating element can be replaced by MsSi2 to run the furnace under oxygen and air up to 1700°C (order picture below right to order spare)\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #ff0000;\"\u003eWarning: Mo heating element cannot be used under air or oxygen at the temperature \u0026gt; 300°C\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas Flow\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eTwo 12 L\/min float flowmeters, each independently controlling one of the two air inlet lines.\u003c\/li\u003e\n\u003cli\u003eOne for purging Inert gas prior to introducing H2 gas\u003c\/li\u003e\n\u003cli\u003eOne for controlling H2 gas flow\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eH2 Gas Burning Control System\u003cbr\u003eand Option Hydrogen Detector\u003cbr\u003e\u003ca href=\"xcdh2\" rel=\"noopener\" target=\"_blank\"\u003e\n\u003cdiv style=\"text-align: start;\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/EQXCDGAS_100x100.jpg\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003c\/div\u003e\n\u003c\/a\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eAn ignition device already installed to incinerate flowing gas and detect burner temperature to ensure H2 burner is in working condition. If H2 does not burn properly, the controller will shut down the H2 gas delivery valve immediately\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #ff0000;\"\u003eWarning: You must install a certified Hydrogen detector in the operation facility to alarm the hydrogen leaking accident. If you can not find it in a local store, please click the link below to order a hydrogen detector from us at an extra cost\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003eOption Hydrogen detector to Enhanced safety for MTI Hydrogen Gas Tube Furnace\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWater Cooling\u003cbr\u003e\n\u003cdiv style=\"text-align: start;\"\u003e\u003ca href=\"kj6200\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan style=\"color: #1f2124;\"\u003e\u003cspan style=\"color: #1f2124;\"\u003e\u003cspan style=\"color: #1f2124;\"\u003e\u003cspan style=\"color: #1f2124;\"\u003e\u003cspan style=\"color: #1f2124;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/KJ6200MAIN.2.1_100x100.jpg\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003eA 58 L\/min recirculating water chiller is \u003cspan style=\"color: rgb(255, 42, 0);\"\u003erequired \u003c\/span\u003efor cooling furnace sealing flange\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eCompliance\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eCE Certified\u003c\/li\u003e\n\u003cli\u003eNRTL or CSA certification is available upon request at the extra cost\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cbr\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003eApplication Notes\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003eAttention: A free course of safety operation training at MTI field is required to purchase this furnace. A customer's side training is also available upon request at extra cost. If the users believe that they have sufficient experience and knowledge to handle the furnace in a dangerous or emergent situation, a liability release agreement must be signed at the purchase. MTI Corp. is not responsible for any damages caused by misuse without safety operation training. Any damages caused by the corrosive and acidic gases are not under the coverage of the MTI One Year Limited Warranty.\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"MTI","offers":[{"title":"Default Title","offer_id":44985155649675,"sku":"KSL1700XH2","price":0.0,"currency_code":"MYR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0716\/4405\/3643\/files\/KSL1700XH2-202504ver.jpg?v=1764854704","url":"https:\/\/mtimalaysia.com\/products\/ksl1700xh2","provider":"MTI Malaysia \u0026 Indonesia","version":"1.0","type":"link"}