{"product_id":"high-throughput-six-channels-vacuum-electrolyte-injection-system-for-cylindrical-cells-msk-113-svm-cnsd","title":"High-Throughput Six-Channels Vacuum Electrolyte Injection System for Cylindrical Cells - MSK-113-SVM-CNSD","description":"\u003cp\u003eWorking diagram for the vacuum electrolyte injection\u003c\/p\u003e\n\u003cp\u003e\u003ca rel=\"noopener\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/MSK-113-SVM-CNSD-electrolyte_injection_diagram.jpg?v=1745017640\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/MSK-113-SVM-CNSD-electrolyte_injection_diagram.jpg?v=1745017640\" alt=\"\" width=\"159\" height=\"173\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 100%; height: 1298.86px;\" cellspacing=\"0\" cellpadding=\"1\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 67.1875px;\"\u003e\n\u003ctd style=\"width: 33.7398%; height: 67.1875px;\"\u003e\n\u003cpre\u003eInput Power\u003c\/pre\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 66.1387%; height: 67.1875px;\"\u003e\n\u003cul\u003e\n\u003cli\u003eAC 110-220 V±10%, 50\/60Hz, Single phase \u003c\/li\u003e\n\u003cli\u003ePower: 750 W\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 83.375px;\"\u003e\n\u003ctd style=\"width: 33.7398%; height: 83.375px;\"\u003e\n\u003cpre\u003e Electrolyte Dispenser\u003c\/pre\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 66.1387%; height: 83.375px;\"\u003e\n\u003cul\u003e\n\u003cli\u003ePrecise electrolyte plunger metering pumps are installed for electrolyte filling;\u003c\/li\u003e\n\u003cli\u003eElectrolyte filling volume and injection rate adjustable via touch screen PLC control       \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 47.5938px;\"\u003e\n\u003ctd style=\"width: 33.7398%; height: 47.5938px;\"\u003e\n\u003cpre\u003e Electrolyte Tank\u003c\/pre\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 66.1387%; height: 47.5938px;\"\u003e\n\u003cul\u003e\n\u003cli\u003eMax. 300ml\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 86.7812px;\"\u003e\n\u003ctd style=\"width: 33.7398%; height: 86.7812px;\"\u003e\n\u003cpre\u003e Cell Size \u003c\/pre\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 66.1387%; height: 86.7812px;\"\u003e\n\u003cul\u003e\n\u003cli\u003e4680 cylindrical cells (other size cylindrical cells are also acceptable by providing customized cell holder)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 114.375px;\"\u003e\n\u003ctd style=\"width: 33.7398%; height: 114.375px;\"\u003e\n\u003cpre\u003e Injection Accuracy\u003c\/pre\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 66.1387%; height: 114.375px;\"\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ctable cellspacing=\"0\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003caddress\u003eElectrolyte Volume (g)\u003c\/address\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003caddress\u003e1g \u003c\/address\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003caddress\u003e5g \u003c\/address\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003caddress\u003e10g\u003c\/address\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003caddress\u003eInjection Accuracy\u003c\/address\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003caddress\u003e ±7%\u003c\/address\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003caddress\u003e±3%\u003c\/address\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003caddress\u003e±2.5%\u003c\/address\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\nInjection Pump Speed: 30 r\/min, Vacuum: -20 KPa, Standing Vacuum: -60 KPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 47.5938px;\"\u003e\n\u003ctd style=\"width: 33.7398%; height: 47.5938px;\"\u003e\n\u003cpre\u003e Positive Pressure Filling\u003c\/pre\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 66.1387%; height: 47.5938px;\"\u003e\n\u003cul\u003e\n\u003cli\u003eMaximum applied pressure 120 KPa, adjustable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 47.5938px;\"\u003e\n\u003ctd style=\"width: 33.7398%; height: 47.5938px;\"\u003e\n\u003cpre\u003e Vacuum Rate\u003c\/pre\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 66.1387%; height: 47.5938px;\"\u003e\n\u003cul\u003e\n\u003cli\u003eMaximum - 95 KPa, adjustable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 106.375px;\"\u003e\n\u003ctd style=\"width: 33.7398%; height: 106.375px;\"\u003e\n\u003cpre\u003eTubing Size\u003c\/pre\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 66.1387%; height: 106.375px;\"\u003e\n\u003cul\u003e\n\u003cli\u003eElectrolyte Flow Tubing (PTFE): O.D. 3 mm, I.D. 2 mm\u003c\/li\u003e\n\u003cli\u003eInjection Tubing (BPT): O.D. 5 mm, I.D. 3 mm\u003c\/li\u003e\n\u003cli\u003eTransfer Tubing (BPT): O.D. 6.4 mm, I.D. 3.2 mm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 134.854px;\"\u003e\n\u003ctd style=\"width: 33.7398%; height: 134.854px;\"\u003e\n\u003cpre\u003e Vacuum Pump (not included)\u003cbr\u003e\u003c\/pre\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cimg style=\"margin-bottom: 16px; float: none;\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/EQFYPmain.2_100x100.jpg\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 66.1387%; height: 134.854px;\"\u003e\n\u003cul\u003e\n\u003cli\u003eDouble-stage rotary vacuum pumps are needed for vacuum diffusion, degassing, and vacuum sealing.\u003c\/li\u003e\n\u003cli\u003ePlease click the picture on the left to purchase separately.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 448.354px;\"\u003e\n\u003ctd style=\"width: 33.7398%; height: 448.354px;\"\u003e\n\u003cpre\u003e Working Gas\u003c\/pre\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 66.1387%; height: 448.354px;\"\u003e\n\u003cul\u003e\n\u003cli\u003e0.5~0.8 MPa high purity compressive inert gas (Ar is preferred) is required for driving the pneumatic system in the glove box\u003c\/li\u003e\n\u003cli\u003eContinues dry inert gas purging for the working chamber is required to maintain a dry atmosphere for electrolyte injection and diffusion \u003c\/li\u003e\n\u003cli\u003eAir compressors and fitting are required if used in the dry room, but not included. \u003ca rel=\"noopener\" href=\"https:\/\/mtimalaysia.com\/products\/ACPHD-3-LD\" target=\"_blank\"\u003eplease click here to order \u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cem\u003eAttention: If a gas cylinder is used instead of an air compressor(pic2), a two-stage pressure regulator(pic1) must be installed on the gas cylinder to limit the pressure within the required working range for safe operation. \u003c\/em\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003e \u003ca rel=\"noopener\" href=\"https:\/\/mtimalaysia.com\/products\/cga580?_pos=1\u0026amp;_psq=CGA-580-LD\u0026amp;_psid=8817af018\u0026amp;_ss=e\u0026amp;_v=1.0\" target=\"_blank\"\u003eClick here to learn the installation of a gas regulator.\u003c\/a\u003e\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\n\u003ca rel=\"noopener\" href=\"https:\/\/mtimalaysia.com\/products\/cga580?_pos=1\u0026amp;_psq=CGA-580-LD\u0026amp;_psid=8817af018\u0026amp;_ss=e\u0026amp;_v=1.0\" target=\"_blank\"\u003e         \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/EQGRCGA580_100x100.jpg\" alt=\"\"\u003e\u003c\/a\u003e     \u003ca rel=\"noopener\" href=\"https:\/\/mtimalaysia.com\/products\/ACPHD-3-LD\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/EQACPHD3.3_100x100.jpg\" alt=\"\"\u003e\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cem\u003e\u003cem\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003c\/em\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 47.5938px;\"\u003e\n\u003ctd style=\"width: 33.7398%; height: 47.5938px;\"\u003e\n\u003cpre\u003eDimension\u003c\/pre\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 66.1387%; height: 47.5938px;\"\u003e\n\u003cul\u003e\n\u003cli\u003eL900*W400*H950mm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 67.1875px;\"\u003e\n\u003ctd style=\"width: 33.7398%; height: 67.1875px;\"\u003e\n\u003cpre\u003e Compliance\u003c\/pre\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 66.1387%; height: 67.1875px;\"\u003e\n\u003cul\u003e\n\u003cli\u003eNRTL Certification is available upon request at an extra cost\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"MTI","offers":[{"title":"Default Title","offer_id":44984739365003,"sku":"MSK-113-SVM-CNSD","price":0.0,"currency_code":"MYR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0716\/4405\/3643\/files\/MSK-113-SVM-CNSD-main_fc33fd7c-829c-41f4-85d3-896076739d2b.jpg?v=1764851777","url":"https:\/\/mtimalaysia.com\/products\/high-throughput-six-channels-vacuum-electrolyte-injection-system-for-cylindrical-cells-msk-113-svm-cnsd","provider":"MTI Malaysia \u0026 Indonesia","version":"1.0","type":"link"}