{"product_id":"gsl-1800x-60-iii","title":"1800C Three Zones Tube Furnace (60mm OD) with Vacuum Flanges \u0026 Quartz Window - GSL-1800X-60-III","description":"\u003cp\u003eGSL-1800X-60-III is a 60mm OD three zones tube furnace with a vacuum sealing flange and 30 mm Dia. quartz window. The center heating zone is 220mm in length, the other two zones are 200mm in length and they are controlled by three precision 30 segments digital temperature controllers independently. All of three zones are heated by Kanthel -1900 grade MoSi2 elements up to 1800°C. The tube furnace can create various thermal gradients by adjusting three zones' temperatures. It is an excellent furnace designed for studying the material's Raman spectrum under high temperatures . also, can be used for epitaxial film growth by CVD.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSPECIFICATIONS \u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cbr\u003eFurnace Structure\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul type=\"disc\"\u003e\n\u003cli\u003eDouble-layer steel case with two cooling fans which ensures low surface temperature\u003c\/li\u003e\n\u003cli\u003eYSZ fibrous insulation is used as internal refractory\u003c\/li\u003e\n\u003cli\u003eHigh-purity fibrous alumina insulation is used as external refractory\u003c\/li\u003e\n\u003cli\u003eIncluded vacuum flange with 30 mm quartz window. The laser beam can penetrate the furnace through the window and sapphire thermal block.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cbr\u003ePower\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e15 KW max (75A air breaker required )\u003c\/li\u003e\n\u003cli\u003e8 KW for normal working temperature\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003eAC 220V three phase \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cbr\u003eMax. Temperature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eEach zone: 1800 °C max. (\u0026lt; 2 hours )\u003c\/li\u003e\n\u003cli\u003e1750°C continuous\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cbr\u003eThermal Block Placement\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv style=\"text-align: start;\"\u003e\u003ca rel=\"noopener\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/Foam_Block_Installation.jpg\" target=\"_blank\"\u003e\u003cimg height=\"43\" width=\"57\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/Foam_Block_Installation.jpg\"\u003e\u003c\/a\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003eHeating Elements\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e14 pcs Kanthal -super-1900 grade MoSi2 heating elements installed\u003cbr\u003e\u003ca rel=\"noopener\" href=\"https:\/\/mtimalaysia.com\/products\/ksksl-1900-m-ld\" target=\"_blank\"\u003e\u003cimg height=\"31\" width=\"49\" alt=\"1800°C Kanthal Super 1900 MoSi2 Heating Element - 300mm- for KSL1800X - KSKSL-1900-M-LD\" src=\"https:\/\/mtimalaysia.com\/cdn\/shop\/files\/hlks-1800_overall_500_41b014da-6b49-4c1a-a56b-ef5fb38f146b.jpg?v=1764854162\u0026amp;width=3840\"\u003e\u003c\/a\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eNormal Heating\/Cooling Rate\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e5°C \/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eHeating Zone Length\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eThree zones: total length: 610 mm (Z1 \u0026amp; Z3 = 195 Z2 = 220 mm)\u003c\/li\u003e\n\u003cli\u003eConstant temperature zone: 300 mm (if set up three-zone at 1600°C)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ca rel=\"noopener\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/Tempprofile.jpg\" target=\"_blank\"\u003e\u003cimg height=\"60\" width=\"104\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/Tempprofile.jpg\"\u003e\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eTemperature Uniformity\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e +\/- 5°C @ 1200°C in the center 170mm zone in length\u003c\/li\u003e\n\u003cli\u003e +\/- 10°C @ 1200°C in the center 400mm zone in length\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eTube Size \u0026amp; Vacuum Flange\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul type=\"disc\"\u003e\n\u003cli\u003e99.8% purity Alumina Tube\u003c\/li\u003e\n\u003cli\u003e60 OD x 54 ID x 1200mm L\u003c\/li\u003e\n\u003cli\u003e60 mm stainless steel water cooling vacuum sealing flange with valve and meter is included\u003c\/li\u003e\n\u003cul\u003e\n\u003cli\u003especial quick clamp flanges for easy installation\u003c\/li\u003e\n\u003cli\u003e30mm Dia x 3 mm double-side polished single-crystal window installed on the flange, which allows the laser beam to go through the tube\u003c\/li\u003e\n\u003cli\u003eIn order to block heating radiation and make the laser bean transparent, Two sapphire rods with two ends polished must be placed inside the furnace ( please order separately )\u003c\/li\u003e\n\u003cli\u003e16L\/min water chiller is required for cooling flange, please click the picture -right to order separately\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"text-align: start;\"\u003e\n\u003cspan style=\"font-size: 0.875rem;\"\u003e   \u003ca rel=\"noopener\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/flange.jpg\" target=\"_blank\"\u003e\u003cimg height=\"31\" width=\"47\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/flange.jpg\"\u003e\u003c\/a\u003e\u003c\/span\u003e    \u003ca rel=\"noopener\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/quickflange.jpg\" target=\"_blank\"\u003e\u003cimg height=\"28\" width=\"42\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/quickflange.jpg\"\u003e\u003c\/a\u003e  \u003ca rel=\"noopener\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/quartzW.jpg\" target=\"_blank\"\u003e\u003cimg height=\"32\" width=\"48\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/quartzW.jpg\"\u003e\u003c\/a\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003e   \u003ca rel=\"noopener\" href=\"https:\/\/mtimalaysia.com\/products\/kj5000\" target=\"_blank\"\u003e\u003cimg height=\"37\" width=\"55\" alt=\"Digital Temperature Controlled Recirculating Water Chiller with 16L \/ min Flow, 2.8K BTU\/hr-KJ5000\" src=\"https:\/\/mtimalaysia.com\/cdn\/shop\/files\/KJ5000_Main_e5591917-0635-4886-8f7d-2c537aa4fc4d.jpg?v=1764854868\u0026amp;width=3840\"\u003e\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cbr\u003eTemperature Control\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eThree digital controllers via SCR (Silicon Controlled Rectifier) power control with phase angle fired\u003c\/li\u003e\n\u003cli\u003eEach controller is 30 programmable segments for precise control of heating, cooling rate and dwells time\u003c\/li\u003e\n\u003cli\u003eBuilt-in PID Auto-Tune function with overheating \u0026amp; broken thermocouple protection\u003c\/li\u003e\n\u003cli\u003eOver-temperature protection and alarm allow for operation without attendant(s)\u003c\/li\u003e\n\u003cli\u003e+\/- 1 ºC temperature accuracy\u003c\/li\u003e\n\u003cli\u003eThree B-type thermocouples (one for each zone)\u003c\/li\u003e\n\u003cli\u003eRS485 Communications Port\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"text-align: start;\"\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003e\u003ca rel=\"noopener\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/Temperature_Control.jpg\" target=\"_blank\"\u003e\u003cimg height=\"37\" width=\"70\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/Temperature_Control.jpg\"\u003e\u003c\/a\u003e       \u003ca rel=\"noopener\" href=\"https:\/\/mtimalaysia.com\/products\/mts02\" target=\"_blank\"\u003e\u003cimg height=\"43\" width=\"64\" alt=\"Temperature Control System for Controlling MTI Furnaces with Laptop - MTS02\" src=\"https:\/\/mtimalaysia.com\/cdn\/shop\/files\/temperaturecontrolsystem_9e05d69b-3c8d-475e-959a-69ec28d61b28.jpg?v=1764854217\u0026amp;width=3840\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEuropean Temperature Controllers (optional upgrade)\u003cbr\u003e\n\u003cdiv style=\"text-align: start;\"\u003e\u003ca rel=\"noopener\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/EurothermFurnace.jpg\" target=\"_blank\"\u003e\u003cimg style=\"margin-bottom: 16px; float: none;\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/EurothermFurnace_100x100.jpg\"\u003e\u003c\/a\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cli\u003e1 heating channel\u003c\/li\u003e\n\u003cli\u003e1 program of 8 or 24 segment\u003c\/li\u003e\n\u003cli\u003eAlarm Relay: Form 'A' and Form ‘C’ built-in \u003c\/li\u003e\n\u003cli\u003eDigital Communications: RS485\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eTemperature Accuracy: ± 0.1ºC\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRecipes:\u003c\/strong\u003e Using a PC tool recipes can be created that can be used to change the operating parameters of the 3000 simply by selecting a new recipe via the HMI. This is very useful where multiple products are processed using the same controller but require different parameters to be set.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Cable \u0026amp; Plug\n\u003cdiv style=\"text-align: start;\"\u003e\u003ca rel=\"noopener\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/10-3AWG_cord.jpg?v=1706055715\" target=\"_blank\"\u003e\u003cimg style=\"margin-bottom: 16px; float: none;\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/10-3AWG_cord_100x100.jpg\" alt=\"\"\u003e\u003c\/a\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eA 10 feet length 8-3 AWG heavy duty UL approved power cable is included\u003c\/li\u003e\n\u003cli\u003eExtra length cable can be ordered by clicking the picture left\u003c\/li\u003e\n\u003cli\u003eThe plug is not included, but you can order from your local hardware store according to the female plug in your lab.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eLaptop, software \u0026amp; WiFi Control (Optional)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv style=\"text-align: start;\"\u003e\n\u003cul\u003e\n\u003cli\u003eBrand new laptop with Microsoft Windows 11.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cem\u003eLabview Based Temperature Control System (\u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003ca rel=\"noopener\" href=\"mts01\" style=\"color: rgb(43, 0, 255);\" target=\"_blank\"\u003eMTS01\u003c\/a\u003e\u003c\/span\u003e)\u003c\/em\u003e\u003c\/strong\u003eenables users to edit temperature profiles, manage heat-treatment recipes, record, and plot data for MTI furnaces.\u003c\/li\u003e\n\u003cli\u003eA wireless remote control provides up to 300 meters of operating range.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003e\u003cem\u003e\u003ca rel=\"noopener\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/wifi_GSL_OTF.jpg\" target=\"_blank\"\u003e\u003cimg height=\"46\" width=\"69\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/wifi_GSL_OTF.jpg\"\u003e\u003c\/a\u003e      \u003ca rel=\"noopener\" href=\"https:\/\/mtimalaysia.com\/products\/mts01\" target=\"_blank\"\u003e\u003cimg height=\"45\" width=\"68\" alt=\"Labview Based Temperature Control System for MTI Single\/Multi Zone Furnaces - MTS01\" src=\"https:\/\/mtimalaysia.com\/cdn\/shop\/files\/temperaturecontrolsystem1_de477652-d154-4758-8bb4-a354d7c4940a.jpg?v=1764854247\u0026amp;width=3840\"\u003e\u003c\/a\u003e\u003c\/em\u003e\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eCompliance\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003ePlease selects the certificate in the options bar:\u003c\/li\u003e\n\u003cli\u003eCE Certificate \u0026amp; UL\/CSA ready: CE approval, ready to pass UL\/CSA certificate at extra cost\u003c\/li\u003e\n\u003cli\u003eUL or TUV certificate - UL approval (UL 61010), \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eApplication Notes\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli style=\"color: rgb(43, 0, 255);\"\u003e\u003ca rel=\"noopener\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/How-to-tube_flange_1.doc?v=1739578848\" target=\"_blank\"\u003e\u003cspan\u003e\u003cspan lang=\"EN-US\"\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003eHow to set up the ceramic tube and vacuum flange for MTI Tube furnace.\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"color: rgb(43, 0, 255);\"\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003ca rel=\"noopener\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/howto-tube.pdf?v=1714583100\" style=\"color: rgb(43, 0, 255);\" target=\"_blank\"\u003eHow to use and maintain Alumina tube in MTI high-temperature tube furnace.\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"color: rgb(43, 0, 255);\"\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003ca rel=\"noopener\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/How-to-Calibrate-MTI-Tube-Furnace.pdf?v=1724186616\" style=\"color: rgb(43, 0, 255);\" target=\"_blank\"\u003eIn order to obtain accurate temperature inside the tube furnace, you need to calibrate the temperature before use, please click here to learn how.\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eOptional Parts\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli style=\"color: rgb(43, 0, 255);\"\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003ca rel=\"noopener\" href=\"ta-60d-m1200\" style=\"color: rgb(43, 0, 255);\" target=\"_blank\"\u003ePlease clicks here to order a spare alumina tube 60 mm O.D.  x1200 mm L\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"color: rgb(43, 0, 255);\"\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003ca rel=\"noopener\" href=\"hel1800t-30300\" style=\"color: rgb(43, 0, 255);\" target=\"_blank\"\u003ePlease click here to order spare 1900oC grade MoSi2 heating elements\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eWarnings\u003c\/span\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cdiv style=\"text-align: start;\"\u003e\u003ca rel=\"noopener\" href=\"cga580\" target=\"_blank\"\u003e\u003cimg style=\"margin-bottom: 16px; float: none;\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/EQGRCGA580_d7ef201c-b5d1-44cd-8189-d6a70bc54de8_100x100.jpg?v=1713311009\"\u003e\u003c\/a\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cbr\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003ca rel=\"noopener\" href=\"cga580\" style=\"color: rgb(43, 0, 255);\" target=\"_blank\"\u003e\u003cspan size=\"2\" face=\"arial, helvetica, sans-serif\"\u003ePlease click here to learn\u003c\/span\u003e\u003cspan size=\"2\" face=\"arial, helvetica, sans-serif\"\u003e the installation of a gas regulator\u003c\/span\u003e. \u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli style=\"color: rgb(255, 42, 0);\"\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003eThe tube furnaces with alumina tube are designed for use under vacuum and low pressure \u0026lt; 0.02 Mpa\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"color: rgb(255, 42, 0);\"\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003eNever use a graphite crucible in the alumina tube.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003e\u003cspan size=\"2\" face=\"arial, helvetica, sans-serif\"\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003e\u003cem\u003eAttention: A two-stage pressure regulator must be installed on the gas cylinder to limit the pressure to below 3 PSI for safe operation.\u003c\/em\u003e\u003c\/span\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003ca rel=\"noopener\" href=\"cga580\" style=\"color: rgb(43, 0, 255);\" target=\"_blank\"\u003e\u003cspan size=\"2\" face=\"arial, helvetica, sans-serif\"\u003eClick here to learn\u003c\/span\u003e\u003cspan size=\"2\" face=\"arial, helvetica, sans-serif\"\u003e the installation of a gas regulator\u003c\/span\u003e.\u003c\/a\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003ca rel=\"noopener\" href=\"cga580\" style=\"color: rgb(43, 0, 255);\" target=\"_blank\"\u003e\u003cspan size=\"2\" face=\"arial, helvetica, sans-serif\"\u003e \u003c\/span\u003e\u003c\/a\u003e\u003c\/span\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"color: rgb(255, 42, 0);\"\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003eThe gas flow rate should be limited to \u0026lt; 200 SCCM ( or 200ml\/min )\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"color: rgb(255, 42, 0);\"\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003eVacuum limit definition for all alumina tube furnaces: * Vacuum pressures may only be safely used up to 1500°C\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"MTI","offers":[{"title":"Default Title","offer_id":44985152405643,"sku":"GSL1800XIII60","price":0.0,"currency_code":"MYR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0716\/4405\/3643\/files\/GSL1800xIII80.1_da035a5e-ce07-45bf-8bd8-e47c487c5afb.jpg?v=1764854666","url":"https:\/\/mtimalaysia.com\/products\/gsl-1800x-60-iii","provider":"MTI Malaysia \u0026 Indonesia","version":"1.0","type":"link"}