{"product_id":"fmf-10","title":"Compact Levitation Cold Crucible Vacuum Melting Furnace10KW, 5g Max.) - FMF-10","description":"FMF-10 is a compact Vacuum Float-Melting System for exploring new generation magnetic alloy and metallic materials. The system uses a 10KW high-frequency induction heater to make metallic sample 5g max) melting by magnetic vortex within a special designed water-cold copper crucible placed inside a vacuum-sealed quartz tube. Therefore, it can produce extra high purity metallic alloy without any contamination. SPECIFICATIONS: Induction Heater Working Voltage: 220VAC three phases) 50\/ 60 Hz. Working Current: 5-25 Amp (30A breaker required) Output Frequency: 50-300 kHz Adjustable Max. Output Power: 10KW Required Water Flowrate: \u0026gt;16 L\/min Two Unit: the Power control unit is separated with the induction heating unit Copper Crucible Dimensions: 27 mm(OD) x 10 mm(ID) x 12 mm depth Water cooling inside Required Water Flowrate: \u0026gt;40 L\/min Max. Load: 5 g for metallic or alloy Required water: \u0026gt; 40 L\/min. Optional Recirculating Water Chiller and Gas required If you don't have water cooling line, please consider our recirculating water chiller 58L\/min at extra cost. High purity Argon gas ( \u0026gt; 5N) tank with pressure regulator is required, but not included. Click here to learn more about the installation of a gas regulator. ( please click the picture below right to order a correct gas regulator ) Quartz Tube \u0026amp; Vacuum Flange One quartz tube included: 32 mm(OD) x 28 mm(ID) x 160 mm(L One pair of Vacuum Flanges with double high-temperature silicone O-rings Max. Vacuum Pressure: 10-2 torr by the mechanical pump (included) 10-5 torr by molecular pump Bottom flange is controlled by an electric motor for easy sample loading and unloading Vacuum Pump One two-stage mechanical pump with exhaust filter is included KF25 adapter, bellow, and valve are included for immediate use The vacuum pump is integrated into the movable steel case Application Notes The Melting System are designed for using under vacuum and low pressure \u0026lt; 0.02 MPa \/ 0.2 Bar\/ 3 PSI Attention : A pressure regulator must be installed on your input gas tank and have the output gas pressure set below 3 PSI with the gas maintained in a continuous flowing condition. Gas build-up with pressure levels exceeding over 3 PSI may cause irreversible damage to the furnace chamber. Never heat the furnace while the gas release valve is closed and a positive pressure condition exists within the furnace chamber. The flow rate for gases should be limited to \u0026lt; 200 SCCM ( or 200ml\/min ) WARNING Read the manual carefully. Monitor and control the inside pressure of the reaction vessel at all time during operation. Otherwise, failure of operation may result in irreparable damage. Compliance NRTL or CSA Certification is available upon request at extra cost\u003cbr\u003e\u003cbr\u003e\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eInduction Heater\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/HF-40AB.jpg\"\u003e\u003cimg alt=\"\" height=\"70\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/HF-40AB.jpg\" width=\"81\"\u003e\u003c\/a\u003e \u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eWorking Voltage: 220VAC three phases) 50\/ 60 Hz. \u003c\/li\u003e\n\u003cli\u003eWorking Current: 5-25 Amp (30A breaker required)\u003c\/li\u003e\n\u003cli\u003eOutput Frequency: 50-300 kHz Adjustable\u003c\/li\u003e\n\u003cli\u003eMax. Output Power: 10KW\u003c\/li\u003e\n\u003cli\u003eRequired Water Flowrate: \u0026gt;16 L\/min\u003c\/li\u003e\n\u003cli\u003eTwo Unit: the Power control unit is separated with the induction heating unit\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCopper Crucible\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/Copper_Crucible-1.jpg\"\u003e\u003cimg alt=\"\" height=\"63\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/Copper_Crucible-1.jpg\" width=\"94\"\u003e\u003c\/a\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eDimensions: 27 mm(OD) x 10 mm(ID) x 12 mm depth\u003c\/li\u003e\n\u003cli\u003eWater cooling inside\u003c\/li\u003e\n\u003cli\u003eRequired Water Flowrate: \u0026gt;40 L\/min\u003c\/li\u003e\n\u003cli\u003eMax. Load: 5 g for metallic or alloy\u003c\/li\u003e\n\u003cli\u003eRequired water: \u0026gt; 40 L\/min.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptional \u003cbr\u003eRecirculating Water Chiller\u003cbr\u003eand Gas required\u003cbr\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eIf you don't have water cooling line, please consider our recirculating water chiller 58L\/min at extra cost.\u003c\/li\u003e\n\u003cli\u003eHigh purity Argon gas ( \u0026gt; 5N) tank with pressure regulator is required, but not included. \u003cstrong\u003e\u003ca href=\"cga580\" rel=\"noopener\" target=\"_blank\"\u003eClick here to learn more about the installation of a gas regulator.\u003c\/a\u003e ( please click the picture below right to order a correct gas regulator )\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n      \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/EQFMF40.jpg\" rel=\"prettyPhoto[products]\" title=\"\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/EQFMF40_100x100.jpg\" style=\"margin-bottom: 16px; float: none;\" title=\"Click to enlarge\"\u003e\u003c\/a\u003e        \u003ca href=\"cga580\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg border=\"0\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/EQGRCGA580_100x100.jpg\" style=\"margin-bottom: 16px; float: none;\" title=\"\"\u003e\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuartz Tube \u0026amp; Vacuum Flange\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eOne quartz tube included: 32 mm(OD) x 28 mm(ID) x 160 mm(L\u003c\/li\u003e\n\u003cli\u003eOne pair of Vacuum Flanges with double high-temperature silicone O-rings\u003c\/li\u003e\n\u003cli\u003eMax. Vacuum Pressure:\u003c\/li\u003e\n\u003cul\u003e\n\u003cli\u003e10-2 torr by the \u003ca href=\"ytp-550-ld\" rel=\"noopener\" target=\"_blank\"\u003emechanical pump\u003c\/a\u003e (included)\u003c\/li\u003e\n\u003cli\u003e10-5 torr by \u003ca href=\"https:\/\/mtixtl.com\/search?q=rotary-vane--pump\u0026amp;options%5Bprefix%5D=last\" rel=\"noopener\" target=\"_blank\"\u003emolecular pump\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003eBottom flange is controlled by an electric motor for easy sample loading and unloading\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/FMF-flange1.jpg\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/FMF-flange1_100x100.jpg\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003c\/a\u003e       \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/FMF-flange2.jpg\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/FMF-flange2_100x100.jpg\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003c\/a\u003e       \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/Untitled.4.png\" rel=\"lightbox\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/Untitled.4_100x100.png\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVacuum Pump\u003cbr\u003e \u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eOne two-stage mechanical pump with exhaust filter is included\u003c\/li\u003e\n\u003cli\u003eKF25 adapter, bellow, and valve are included for immediate use\u003c\/li\u003e\n\u003cli\u003eThe vacuum pump is integrated into the movable steel case\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"FYP\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg border=\"0\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/EQFYPmain2_new_100x100.jpg\" style=\"margin-bottom: 16px; float: none;\" title=\"\"\u003e\u003c\/a\u003e        \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/fmf-23.jpg?v=1706114470\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/fmf-23_100x100.jpg\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication Notes\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli style=\"color: rgb(255, 42, 0);\"\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003eThe Melting System are designed for using under vacuum and low pressure \u0026lt; 0.02 MPa \/ 0.2 Bar\/ 3 PSI \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: rgb(255, 42, 0);\"\u003e\u003cstrong\u003eAttention\u003c\/strong\u003e: \u003c\/span\u003eA pressure regulator must be installed on your input gas tank and have the output gas pressure set below 3 PSI with the gas maintained in a continuous flowing condition. Gas build-up with pressure levels exceeding over 3 PSI may cause irreversible damage to the furnace chamber.\u003c\/li\u003e\n\u003cli\u003eNever heat the furnace while the gas release valve is closed and a positive pressure condition exists within the furnace chamber. \u003c\/li\u003e\n\u003cli style=\"color: rgb(255, 42, 0);\"\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003eThe flow rate for gases should be limited to \u0026lt; 200 SCCM ( or 200ml\/min )\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"color: rgb(255, 42, 0);\"\u003e\n\u003cspan style=\"color: rgb(255, 42, 0);\"\u003e\u003cstrong\u003e WARNING \u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003eRead the manual carefully. Monitor and control the inside pressure of the reaction vessel at all time during operation. Otherwise, failure of operation may result in irreparable damage.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompliance\u003c\/td\u003e\n\u003ctd\u003eNRTL or CSA Certification is available upon request at extra cost\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"MTI","offers":[{"title":"Default Title","offer_id":44985170559115,"sku":"EQ-FMF-10","price":0.0,"currency_code":"MYR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0716\/4405\/3643\/files\/EQFMF10.1_b6e326ef-5788-4533-b651-f6e9981c7b4d.jpg?v=1764854931","url":"https:\/\/mtimalaysia.com\/products\/fmf-10","provider":"MTI Malaysia \u0026 Indonesia","version":"1.0","type":"link"}