{"product_id":"bst8-hbp-5a","title":"8-Channel Hybrid Battery Tester and Potentiostat up to 5A-5V w\/ Laptop \u0026 Software - BST8-HBP-5A","description":"\u003cp\u003eBST8-5A is an eight-channel hybrid battery analyzer and potentiostat for battery and fundamental electrochemical research with a current range from 15nA ~ 5A , up to 5V. This analyzer can measure all kinds of \u003cspan style=\"color: rgb(255, 42, 0);\"\u003efull batteries, half batteries, and three-electrode electrochemical tests,\u003c\/span\u003e which is suitable for battery material and finished product research, farad capacitor material, and finished product research. The purchase comes with a brand-new laptop with the latest version of controller software installed and calibrated for immediate use.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFEATURES \u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSupports precision research and testing with 0.01% voltage and current accuracy.\u003c\/li\u003e\n\u003cli\u003e Supports high-rate fast charge research, 30C can achieve 0.01% capacity accuracy; 100C can reach 0.1% capacity accuracy.\u003c\/li\u003e\n\u003cli\u003eSupports custom pulse test with a minimum pulse width of 2ms.\u003c\/li\u003e\n\u003cli\u003eFull coverage of the measurement records of the voltage, current, capacity, energy, efficiency, capacitance, internal resistance, and other parameters required for the study.\u003c\/li\u003e\n\u003cli\u003eThe device comes with UPS and storage to effectively prevent data loss and damage caused by downtime, sudden power failure, network failure, etc.\u003c\/li\u003e\n\u003cli\u003eSupports multiple working conditions testing such as CATC, NEDC, and WLTC, which can accurately simulate the actual usage scenarios of batteries.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eElectricity Requirement\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eAC220V ±10% 50Hz, 400W\u003c\/li\u003e\n\u003cli\u003eAC110V ±10% 60Hz, 400W\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOperation Interface\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/operation_interface.jpg\"\u003e\u003cimg alt=\"\" height=\"60\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/operation_interface.jpg\" width=\"111\"\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eCurrent\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eFour ranges of max. current are included and switchable on the device\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRange 1: 0 - 150uA;\u003c\/li\u003e\n\u003cli\u003eRange 2: 150uA - 5mA;\u003c\/li\u003e\n\u003cli\u003eRange 3: 5mA - 150mA;\u003c\/li\u003e\n\u003cli\u003eRange 4: 5A;\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAccuracy: ± (0.01% of full scale)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eVoltage\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eRange: 0 - 5V programmable\u003c\/li\u003e\n\u003cli\u003eAccuracy: ± (0.01% of full scale)\u003c\/li\u003e\n\u003cli\u003eVoltage monitor is possible when no testing process is running.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eTime\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cli\u003eAccuracy: ≤±5 us\/s (Equipment autonomous control, no communication, and other time delay errors)\u003c\/li\u003e\n\u003cli\u003eMinimum Step Time: 20ms\u003c\/li\u003e\n\u003cli\u003eMinimum Pulse Time: 2ms\u003c\/li\u003e\n\u003cli\u003eSampling Interval: ≤10ms\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eInput Impedance\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cli\u003e≥10GΩInput base current \u0026lt; 0.5nA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eData Record\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eSampling Rate: 100HzSampling interval 10ms\u003c\/li\u003e\n\u003cli\u003eSetting Method: Interval time, Sampling rate, Interval current, Interval capacity, Interval voltage, Interval energy\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMax. Program steps\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e1024 steps\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOutput\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eFour electrodes (support reference electrode test)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e10\/100M Ethernet(RJ45), USB(Console)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Environment\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eTemperature 0~4023±2 Optimum accuracy\u003c\/li\u003e\n\u003cli\u003eHumidity ≤ 90% No condensation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003e\n\u003cp\u003eProcess Control\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eEight independent programmable channels. Each channel can work under different modes and functions independently\u003c\/li\u003e\n\u003cli\u003eWorking modes Include:\u003c\/li\u003e\n\u003cul\u003e\n\u003cli\u003eHOLD \/ CC \/ CV \/ CCCV \/ CRATE \/ CP \/ CR \/ CPULSE \/ CSLOPE \/ DC \/ DV \/ DCDV \/ DRATE \/ DP \/ DR \/ DPULSE \/ DSLOPE\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eEnd Conditions: \n\u003cul\u003e\n\u003cli\u003eTIME \/ VOLTAGE \/ CURRENT \/ POWER \/ CAPACITY \/ ENERGY \/ LOOPS \/ PHASE CYCLE\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eProtective Function: \n\u003cul\u003e\n\u003cli\u003ePower-off data protection, Net break protection\u003c\/li\u003e\n\u003cli\u003eUser-defined safety: Over voltage, Under voltage, Over current, Over rate, Over capacity.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eTest Reports and Curves for Analysis\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eVarious graphs and curves can be created by software based on user definition. (Voltage-time curve, current-time curve, capacity-voltage curve, loops times charge\/discharge capacity curve, loops times charge\/ discharge efficiency curve, etc)\u003c\/li\u003e\n\u003cli\u003eData reports are created by software in \u003cstrong\u003eexcel format\u003c\/strong\u003e. A copy of MS Excel must be installed in order to export data. The user can easily compare the performance of the batteries tested in channels both visually and statistically.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eFunction\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eDCIR, Capacitance capacity calculation, Step pulse, Three-electrode testReference test, DQ\/DV\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eBattery clips\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e8 set of alligator clips for coin cell connection.\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/alligator_clips_for_coin_cell.jpg\"\u003e\u003cimg alt=\"\" height=\"76\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/alligator_clips_for_coin_cell.jpg\" width=\"100\"\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cbr\u003eLaptop Computer\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eBrand new laptop with Windows 11 for data export. (Excel activation is required.)\u003c\/li\u003e\n\u003cli\u003eSoftware is installed and calibrated for \u003cstrong\u003eimmediate use.\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eNotice: We strongly suggest you keep an instant backup of the collected data using an external hard drive.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eCompliance\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli style=\"color: rgb(255, 42, 0);\"\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003eCE Certified\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"color: rgb(255, 42, 0);\"\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003eNRTL or CSA certification is available upon request at an extra cost\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cbr\u003eApplication Notes \u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli style=\"color: rgb(255, 42, 0);\"\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003eWarning: Please choose NEVER for Screen and Sleep off in the Power\u0026amp; Sleep setting of your computer, or it may lose connection from the battery analyzer.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"MTI","offers":[{"title":"Default Title","offer_id":44984839307403,"sku":"BST8-HBP-5A","price":0.0,"currency_code":"MYR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0716\/4405\/3643\/files\/tester.1.1.1_19607d2b-2d11-4340-8bc5-82bc7b710783.jpg?v=1764851145","url":"https:\/\/mtimalaysia.com\/products\/bst8-hbp-5a","provider":"MTI Malaysia \u0026 Indonesia","version":"1.0","type":"link"}