{"title":"Hot Lamination","description":"","products":[{"product_id":"jtfm380","title":"Hot Rolling Laminating Press up to 130C with Max.1200 kgf \u0026 Optional 340 \/ 480 \/ 1050 mm Width - JTFM380","description":"JTFM380 DC6 is a 130°C max. double-sided laminating machine, which can apply pressure by the built-in manual hydraulic pump up to 1200 Kg force with optional widths, of 340mm, 480 mm, and 1000 mm. It is an excellent tool for research on multilayer LCP, flexible electronic devices, and solid-state Li-Ion batteries. SPECIFICATIONS: Model JTFM380 JTFM520 JTFM 1050 Laminating Width 340mm Max 480mm Max 1000 mm Max Laminating Width 3 mm Max Roller diameter Φ192×380mm Φ 192×520mm Φ 216×1050mm The top roller is made of A3 Steel and the bottom roller is made of high-temperature rubber Only the top steel roller is heated Both rollers made of SS304 are available upon request Laminating Speed 0.5-30m\/min 0.5-30m\/min 0.5-30 m\/ min Winding motor DC motor with tension-controlled Laminating Temperature Range 60-130°C 60-130°C 60-130°C Max. Pressure Pressure is applied by a manual hydraulic pump up to 1200 Kg with a pressure gauge Pressure gauge vs. the force applied to the roller as below Gauge Pressure (MPa 2 4 6 8 10 Force applied to the rollers (Kg) 240 360 720 960 1200 Optional: You may use an electric oil pump to achieve automatic pressure setting up to 15 MPa as the link below Power 220VAC +\/- 10% , Single phase, 50\/60Hz, 5kW 220VAC +\/- 10% , Single phase, 50\/60Hz, 7kW 220VAC +\/- 10%, Three phases, (single phase is available with a boost frequency converter), 50\/60Hz, 7 kW Compliance NRTL or CSA certification is available upon request at the extra cost\u003cbr\u003e\u003cbr\u003e\u003ctable border=\"1\" cellpadding=\"1\" cellspacing=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e JTFM380\u003c\/td\u003e\n\u003ctd\u003e JTFM520\u003c\/td\u003e\n\u003ctd\u003e JTFM 1050\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Laminating Width\u003c\/td\u003e\n\u003ctd\u003e 340mm Max\u003c\/td\u003e\n\u003ctd\u003e 480mm Max\u003c\/td\u003e\n\u003ctd\u003e 1000 mm Max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e Laminating Width\u003c\/td\u003e\n\u003ctd colspan=\"3\" style=\"text-align: center;\"\u003e3 mm Max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eRoller diameter\u003c\/td\u003e\n\u003ctd\u003e Φ192×380mm\u003c\/td\u003e\n\u003ctd\u003e \u003cspan lang=\"ZH-CN\"\u003eΦ\u003c\/span\u003e192×520mm\u003c\/td\u003e\n\u003ctd\u003e \u003cspan lang=\"ZH-CN\"\u003eΦ\u003c\/span\u003e216×1050mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\n\u003cul\u003e\n\u003cli\u003eThe top roller is made of A3 Steel and the bottom roller is made of high-temperature rubber\u003c\/li\u003e\n\u003cli\u003eOnly the top steel roller is heated\u003c\/li\u003e\n\u003cli\u003eBoth rollers made of SS304 are available upon request\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLaminating Speed \u003c\/td\u003e\n\u003ctd\u003e 0.5-30m\/min\u003c\/td\u003e\n\u003ctd\u003e0.5-30m\/min\u003c\/td\u003e\n\u003ctd\u003e 0.5-30 m\/ min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Winding motor\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e DC motor with tension-controlled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLaminating Temperature Range\u003c\/td\u003e\n\u003ctd\u003e 60-130°C\u003c\/td\u003e\n\u003ctd\u003e60-130°C\u003c\/td\u003e\n\u003ctd\u003e60-130°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Pressure \u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e\n\u003cul\u003e\n\u003cli\u003ePressure is applied by a manual hydraulic pump up to 1200 Kg with a pressure gauge\u003c\/li\u003e\n\u003cli\u003ePressure gauge vs. the force applied to the roller as below \u003c\/li\u003e\n\u003cli\u003e\n\u003ctable border=\"1\" cellspacing=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge Pressure (MPa\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003ctd\u003e10 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForce applied to the rollers (Kg)\u003c\/td\u003e\n\u003ctd\u003e240\u003c\/td\u003e\n\u003ctd\u003e360\u003c\/td\u003e\n\u003ctd\u003e720\u003c\/td\u003e\n\u003ctd\u003e960\u003c\/td\u003e\n\u003ctd\u003e1200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/li\u003e\n\u003cli\u003eOptional: You may use an electric oil pump to achieve automatic pressure setting up to 15 MPa as the link below\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ca href=\"YLJ-PE\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg border=\"0\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/Pump70Mpa.2_100x100.jpg\" style=\"margin-bottom: 16px; float: none;\" title=\"\"\u003e\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Power\u003c\/td\u003e\n\u003ctd\u003e220VAC +\/- 10% , Single phase, 50\/60Hz,\u003cbr\u003e5kW\u003c\/td\u003e\n\u003ctd\u003e220VAC +\/- 10% , Single phase, 50\/60Hz,\u003cbr\u003e7kW\u003c\/td\u003e\n\u003ctd\u003e220VAC +\/- 10%, Three phases, (single phase is available with a boost frequency converter), 50\/60Hz,\u003cbr\u003e7 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompliance\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e\n\u003cul\u003e\n\u003cli\u003eNRTL or CSA certification is available upon request at the extra cost\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e, \u003ctable border=\"1\" cellspacing=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge Pressure (MPa\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003ctd\u003e10 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForce applied to the rollers (Kg)\u003c\/td\u003e\n\u003ctd\u003e240\u003c\/td\u003e\n\u003ctd\u003e360\u003c\/td\u003e\n\u003ctd\u003e720\u003c\/td\u003e\n\u003ctd\u003e960\u003c\/td\u003e\n\u003ctd\u003e1200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"MTI","offers":[{"title":"340 mm","offer_id":44984749686923,"sku":"JTFM380","price":0.0,"currency_code":"MYR","in_stock":false},{"title":"480 mm","offer_id":44984749719691,"sku":"JTFM520","price":0.0,"currency_code":"MYR","in_stock":false},{"title":"1050 mm","offer_id":44984749752459,"sku":"JTFM1050","price":0.0,"currency_code":"MYR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0716\/4405\/3643\/files\/JTFM-380.1_18ee828c-6105-40e4-8499-5795583964cb.png?v=1764851825"},{"product_id":"ylj-hp80","title":"9 KN (+\/- 5N) Lamination Hot Press (200x150 mm) up to 150C with Precision Pressure Controller - YLJHP80","description":"YLJ-HP80 is a Pneumatic Press with a precision constant pressure controller within +\/- 0.5 Kg up to 9KN and 150°C. It is designed for testing the effect of pressure on solid-state battery performance, and also can be used as the SEI formation or electrode lamination under hot pressing. This device is Ar gas compatible and can be used in the glovebox. SPECIFICATIONS: Pneumatic Press Max. Load: 9KN ( 900 Kg) Pneumatic cylinder travel distance 200 mm Max. Working area: 200 mm W x 150 mm D Max. working height: 0 - 110 mm Driven by any standard air compressor or inert gas tank, which is not included. 0.4~0.8Mpa of air pressure supply is needed. Please click the picture below to order. If alignment for upper and bottom plates is not ideal, please slightly adjust the four screws at corners. Attention: If a gas cylinder is used instead of an air compressor(pic2), a two-stage pressure regulator(pic1) must be installed on the gas cylinder to limit the pressure within the required working range for safe operation. Click here to learn about the installation of a gas regulator. Note: If used in the glove, an inert gas cylinder must be used for the gas source. pic1 pic2 Heating Plates Two heating plates with two independent single point temperature controllers Single point PID temperature control with +\/- 1ºC accuracy Heated plate area: 200 mm W x 150 mm D Max. working temperature: 200°C (continuous) Heating Rate: 10°C\/ minute Max. Power: 208 - 240V V (50\/60 Hz), 1200 W, Single phase To use at 110VAC, you need order a 1500W transformer ( Click picture left to order ) Pressure Controller Pneumatic cylinder bore size 125mm diameter. Digital pressure controller with PID tuning, which can keep the constant pressure at setting value. 30 segments programmable. (max working time: 9999 minutes for each segment) Pressure Accuracy: +\/- 0.5 kg \/cm2 Optional: You may order the load cell below to calibrate the applied pressure force from time to time Feed-Through (Optional) If the press is used in a glove box, two separate feed-throughs are required One feed-through for gas tubes.($295.00\/set) One feed-through for power and communication cords.($500.00\/set) The feed-throughs are not included in the standard package, please contact us for more information. Compliance CE approval NRTL or CSA certification is available upon request at an extra cost of $3500.00 Calibration: Please use NIST certified load sensor to calibrate the pressure by yourselves. ( Please click the picture below to order: Application Notes It can be used as a jig for compressing pressure adjustable split test cell, please click the picture below for details: compress-able coin cell Compress-able pouch cell\u003cbr\u003e\u003cbr\u003e\u003ctable cellpadding=\"0\" cellspacing=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePneumatic Press\u003cbr\u003e\u003cbr\u003e\n\u003cdiv\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/YLJ-HP80_Description.jpg?v=1706137058\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/YLJ-HP80_Description_100x100.jpg\"\u003e\u003c\/a\u003e\u003c\/div\u003e\n\u003cbr\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eMax. Load: 9KN ( 900 Kg)\u003c\/li\u003e\n\u003cli\u003ePneumatic cylinder travel distance 200 mm Max.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eWorking area: 200 mm W x 150 mm D\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eMax. working height: 0 - 110 mm\u003c\/li\u003e\n\u003cli\u003eDriven by any standard air compressor or inert gas tank, which is not included. 0.4~0.8Mpa of air pressure supply is needed. Please click the picture below to order.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eIf\u003c\/span\u003e\u003cspan\u003e alignment for upper and bottom plates is not ideal, please slightly adjust the four screws at corners.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003e              \u003c\/span\u003e\n\u003cdiv style=\"text-align: start;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/alignment_adjustment_for_HP-80.png?v=1737767262\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/alignment_adjustment_for_HP-80_100x100.png?v=1737767262\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003c\/a\u003e\u003c\/div\u003e\n\u003cspan\u003e     \u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eAttention: If a gas cylinder is used instead of an air compressor(pic2), a two-stage pressure regulator(pic1) must be installed on the gas cylinder to limit the pressure within the required working range for safe operation. \u003ca href=\"CGA-580-LD\" rel=\"noopener\" target=\"_blank\"\u003eClick here to learn about the installation of a gas regulator.\u003c\/a\u003e\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eNote: If used in the glove, an inert gas cylinder must be used for the gas source.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003ca href=\"CGA-580-LD\" rel=\"noopener\" target=\"_blank\"\u003e\u003cem\u003e\u003cstrong\u003e\u003cem\u003e\u003cstrong\u003e\u003cem\u003e\u003cstrong\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/EQGRCGA580_100x100.jpg\"\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003c\/a\u003e\u003cem\u003e\u003cstrong\u003e pic1 \u003cem\u003e\u003cstrong\u003e\u003cem\u003e\u003cstrong\u003e\u003ca href=\"ACPHD-3-LD\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/EQACPHD3.3_100x100.jpg\"\u003e\u003c\/a\u003e pic2\u003c\/strong\u003e\u003c\/em\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003c\/strong\u003e\u003c\/em\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eHeating Plates\u003c\/p\u003e\n\u003cdiv style=\"text-align: start;\"\u003e\u003ca href=\"tf-220110-1500-ld\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/300wtransf1_a9d91d73-21ac-4721-b312-f4634e175a98_100x100.jpg?v=1713396606\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003c\/a\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eTwo heating plates with two independent single point temperature controllers \u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"color: rgb(255, 42, 0);\"\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003eSingle point PID temperature control with +\/- 1ºC accuracy\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eHeated plate area: 200 mm W x 150 mm D\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMax. working temperature: 200°C (continuous)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eHeating Rate: 10°C\/ minute Max.\u003cbr\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ePower: 208 - 240V V (50\/60 Hz), 1200 W, Single phase\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eTo use at 110VAC, you need order \u003ca href=\"tf-220110-1500-ld\" rel=\"noopener\" target=\"_blank\"\u003ea 1500W transformer\u003c\/a\u003e ( Click picture left to order )\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure Controller\u003cbr\u003e\n\u003cdiv\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/EQREG1050.jpg?v=1706220471\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/EQREG1050_100x100.jpg\"\u003e\u003c\/a\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003ePneumatic cylinder bore size 125mm diameter.\u003c\/li\u003e\n\u003cli\u003eDigital pressure controller with PID tuning, which can keep the constant pressure at setting value.\u003c\/li\u003e\n\u003cli\u003e30 segments programmable. (max working time: 9999 minutes for each segment)\u003c\/li\u003e\n\u003cli\u003ePressure Accuracy:\u003cstrong\u003e +\/- 0.5 kg \/cm2\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eOptional: You may order the load cell below to calibrate the applied pressure force from time to time\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFeed-Through (Optional)\u003cbr\u003e\n\u003cdiv style=\"text-align: start;\"\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/FeedtrhoughKF40installation.jpg?v=1706219580\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/FeedtrhoughKF40installation_50x50.jpg?v=1706219580\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003c\/a\u003e\u003ca class=\"MagicThumb\" href=\"https:\/\/mti-kjgroup.com\/images\/products\/detail\/FeedtrhoughKF40installation.jpg\" id=\"mt-458516183112\"\u003e\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eIf the press is used in a glove box, two separate feed-throughs are required\u003c\/li\u003e\n\u003cul\u003e\n\u003cli\u003eOne feed-through for gas tubes.($295.00\/set)\u003c\/li\u003e\n\u003cli\u003eOne feed-through for power and communication cords.($500.00\/set)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003eThe feed-throughs are not included in the standard package, please contact us for more information.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompliance\u003cbr\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eCE approval\u003c\/li\u003e\n\u003cli\u003eNRTL or CSA certification is available upon request at an extra cost of $3500.00\u003c\/li\u003e\n\u003cli\u003eCalibration: Please use NIST certified load sensor to calibrate the pressure by yourselves. ( Please click the picture below to order:\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication Notes\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eIt can be used as a jig for compressing pressure adjustable split test cell, please click the picture below for details:\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\n\u003ca href=\"PSC\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/EQPSC.1_100x100.jpg\"\u003e\u003c\/a\u003e\u003cstrong\u003e compress-able coin cell \u003cstrong\u003e\u003ca href=\"PSPC\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg alt=\"\" border=\"0\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/splipouchcell1_100x100.jpg\" title=\"\"\u003e\u003c\/a\u003eCompress-able pouch cell\u003c\/strong\u003e\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"MTI","offers":[{"title":"Default Title","offer_id":44985070551179,"sku":"YLJHP80","price":0.0,"currency_code":"MYR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0716\/4405\/3643\/files\/YLJ-HP80_Main_b2e086f6-2aa4-4fc4-be1e-43ab04b85171.jpg?v=1764853999"},{"product_id":"ylj-hp100-xx","title":"500°C or 750°C 24T Laminating Hot Press (135x135 mm) with Dual Temp. Controller - YLJ-HP100-XX","description":"YLJ-HP100XX is a optional 500°C or 750°C Max. lamination hot press, which consists of a 24T hydraulic press with two heated platens. The temperatures of the heated platens are controlled by two digital temperature controllers separately. The platens ( 135 x 135 mm area) are made of hardened Cr12MoV or SS310 alloy with a flat surface. Water cooling jackets are installed with the heating platen that allows the heated plate to get faster cooling. One pressure gauge (300 kN) is also mounted to monitor the pressure applied on the platen. It is an excellent tool to prepare polymer and ceramic samples, and SOEC cells (solid-oxide electrolyzer cells). SPECIFICATIONS: Hydraulic Press The hydraulic pump and hydraulic cylinder are separated for easy replacement Max. Force: 24T Manual operation Max. Working Pressure Gauge Displayed Pressure Value (MPa) 5 10 15 20 25 30 35 40 45 Actual Force Applied on the Hydraulic Cylinder (Ton) 4 6 9 11 14 17 19 22 24 The actual force applied to the Hydraulic Cylinder (Ton) is equal to the force applied to your working piece For calculating the actual pressure (MPa) applied to your working piece, please follow the equations below: P = T\/(πr^2) x g x 10 P: Pressure (MPa) applied to your working piece T: Force (Ton) applied to the Hydraulic Cylinder g: Standard gravity. g ≈ 9.8 m\/s 2 π: ~3.14 r: Radius (cm) of the working piece *1 Metric Ton = 1000 kg; 1 MPa ≈ 10 kgf\/cm 2 Pressure Gauge Measuring Accuracy is ± 1.5 T The reading from pressure gauge is different with that applied on samples. Heated Platen Area Platen Area: 135 mm x 135 mm Material: Harden Cr12MoV alloy for 500°C version ( SS310 for 750oC version ) Surface: Flattening with CNC grinding The parallelism between two plates: \u0026lt; 0.05 mm within 10\"x10\" area Plate surface roughness: \u0026lt; 2 microns Max. Travel Distance 58 mm (that means the thickest sample should be below 58 mm). Do not raise the bottom cylinder (piston) more than its maximum traveling distance (80 mm) Max. Working Temperature 450°C continuous with water cooling 500°C for less than 30 minutes with water cooling 750°C version is available upon request at extra cost. Please choose from the product option Heating Rate \u0026amp; Cooling Rate ≤ 5°C\/min Water Cooling Two 1\/4\" water pipe connectors. A water chiller is required but not included. Our KJ5000 water chiller is available. An optional electric hydraulic pump for automatic pressure control is also available. (Pic below ) Temperature Control Two digital controllers are installed in one box with 30 segments programmable and auto-tune faction Temperature accuracy ±2°C. Power Requirement 208 - 240 VAC, 50\/60Hz, single phase 2.5 kW max. 15 A circuit breaker is required for 220 V, 5' length power cable included, but no plug Compliance CE Certified for the whole furnace NRTL (UL 61010) or CSA Certification is available upon request, additional charges will apply Application not This hot -press can be used inside glovebox with Ar and N2 gases\u003cbr\u003e\u003cbr\u003e\u003ctable border=\"1\" cellpadding=\"1\" cellspacing=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eHydraulic Press\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eThe hydraulic pump and hydraulic cylinder are separated for easy replacement\u003c\/li\u003e\n\u003cli\u003eMax. Force: 24T\u003c\/li\u003e\n\u003cli\u003eManual operation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Working Pressure\u003c\/td\u003e\n\u003ctd\u003e\n\u003ctable border=\"1\" cellspacing=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge Displayed Pressure Value (MPa)\u003c\/td\u003e\n\u003ctd\u003e 5\u003c\/td\u003e\n\u003ctd\u003e 10 \u003c\/td\u003e\n\u003ctd\u003e 15 \u003c\/td\u003e\n\u003ctd\u003e 20 \u003c\/td\u003e\n\u003ctd\u003e 25 \u003c\/td\u003e\n\u003ctd\u003e 30 \u003c\/td\u003e\n\u003ctd\u003e35 \u003c\/td\u003e\n\u003ctd\u003e 40 \u003c\/td\u003e\n\u003ctd\u003e 45 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eActual Force Applied on the Hydraulic Cylinder (Ton)\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003e 6\u003c\/td\u003e\n\u003ctd\u003e 9\u003c\/td\u003e\n\u003ctd\u003e 11 \u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003ctd\u003e 17 \u003c\/td\u003e\n\u003ctd\u003e19\u003c\/td\u003e\n\u003ctd\u003e 22 \u003c\/td\u003e\n\u003ctd\u003e24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cul\u003e\n\u003cli\u003eThe actual force applied to the Hydraulic Cylinder (Ton) is equal to the force applied to your working piece\u003c\/li\u003e\n\u003cli\u003eFor calculating the actual pressure (MPa) applied to your working piece, please follow the equations below:\u003c\/li\u003e\n\u003cli\u003eP = T\/(πr^2) x g x 10\u003c\/li\u003e\n\u003cul\u003e\n\u003cli\u003eP: Pressure (MPa) applied to your working piece\u003c\/li\u003e\n\u003cli\u003eT: Force (Ton) applied to the Hydraulic Cylinder \u003c\/li\u003e\n\u003cli\u003eg: Standard gravity. g ≈ 9.8 m\/s\u003csup\u003e2\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003eπ: ~3.14\u003c\/li\u003e\n\u003cli\u003er: Radius (cm) of the working piece\u003c\/li\u003e\n\u003cli\u003e*1 Metric Ton = 1000 kg; 1 MPa ≈ 10 kgf\/cm\u003csup\u003e2\u003c\/sup\u003e \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure Gauge\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eMeasuring Accuracy is ± 1.5 T\u003c\/li\u003e\n\u003cli style=\"color: rgb(255, 42, 0);\"\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003eThe reading from pressure gauge is different with that applied on samples.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeated Platen Area\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003ePlaten Area: 135 mm x 135 mm \u003c\/li\u003e\n\u003cli\u003eMaterial: Harden Cr12MoV alloy for 500°C version ( \u003cspan style=\"color: rgb(255, 42, 0);\"\u003eSS310 for 750oC version\u003c\/span\u003e)\u003c\/li\u003e\n\u003cli\u003eSurface: Flattening with CNC grinding\u003c\/li\u003e\n\u003cli\u003eThe parallelism between two plates: \u0026lt; 0.05 mm within 10\"x10\" area\u003c\/li\u003e\n\u003cli\u003ePlate surface roughness: \u0026lt; 2 microns\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003eMax. Travel Distance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e58 mm (that means the thickest sample should be below 58 mm).\u003c\/li\u003e\n\u003cli style=\"color: rgb(255, 42, 0);\"\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003eDo not raise the bottom cylinder (piston) more than its maximum traveling distance (80 mm)\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003eMax. Working Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e450°C continuous with water cooling\u003c\/li\u003e\n\u003cli\u003e500°C for less than 30 minutes with water cooling\u003c\/li\u003e\n\u003cli style=\"color: rgb(255, 42, 0);\"\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003e750°C version is available upon request at extra cost. Please choose from the product option\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Rate \u0026amp; Cooling Rate\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e≤ 5°C\/min\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWater Cooling\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eTwo 1\/4\" water pipe connectors. \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eA water chiller is required but not included.\u003c\/strong\u003e \u003c\/li\u003e\n\u003cli\u003eOur \u003ca href=\"KJ5000\" rel=\"noopener\" target=\"_blank\"\u003eKJ5000 water \u003c\/a\u003echiller is available. \u003c\/li\u003e\n\u003cli\u003eAn optional electric hydraulic pump for automatic pressure control is also available. (Pic below )\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003ca href=\"KJ5000\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/EQ-KJ5000-220-hide.1_100x100.jpg\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003c\/a\u003e  \u003ca href=\"YLJ-PE\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/IMG20180919150550_100x100.jpg\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003c\/a\u003e    \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/HP-100-4.1.jpg?v=1706219653\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/HP-100-4.1_100x100.jpg\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/HP-100-4.1.jpg\" rel=\"lightbox\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Control\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eTwo digital controllers are installed in one box with 30 segments programmable and auto-tune faction\u003c\/li\u003e\n\u003cli\u003eTemperature accuracy ±2°C.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Requirement\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e208 - 240 VAC, 50\/60Hz, single phase\u003c\/li\u003e\n\u003cli\u003e2.5 kW max.\u003c\/li\u003e\n\u003cli\u003e15 A circuit breaker is required for 220 V, 5' length power cable included, but no plug\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompliance\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eCE Certified for the whole furnace\u003c\/li\u003e\n\u003cli\u003eNRTL (UL 61010) or CSA Certification is available upon request, additional charges will apply\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Application not\u003c\/td\u003e\n\u003ctd\u003eThis hot -press can be used inside glovebox with Ar and N2 gases\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e, \u003ctable border=\"1\" cellspacing=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge Displayed Pressure Value (MPa)\u003c\/td\u003e\n\u003ctd\u003e 5\u003c\/td\u003e\n\u003ctd\u003e 10 \u003c\/td\u003e\n\u003ctd\u003e 15 \u003c\/td\u003e\n\u003ctd\u003e 20 \u003c\/td\u003e\n\u003ctd\u003e 25 \u003c\/td\u003e\n\u003ctd\u003e 30 \u003c\/td\u003e\n\u003ctd\u003e35 \u003c\/td\u003e\n\u003ctd\u003e 40 \u003c\/td\u003e\n\u003ctd\u003e 45 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eActual Force Applied on the Hydraulic Cylinder (Ton)\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003e 6\u003c\/td\u003e\n\u003ctd\u003e 9\u003c\/td\u003e\n\u003ctd\u003e 11 \u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003ctd\u003e 17 \u003c\/td\u003e\n\u003ctd\u003e19\u003c\/td\u003e\n\u003ctd\u003e 22 \u003c\/td\u003e\n\u003ctd\u003e24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"MTI","offers":[{"title":"500°C Max","offer_id":44985070583947,"sku":"YLJHP100","price":0.0,"currency_code":"MYR","in_stock":false},{"title":"750°C Max","offer_id":44985070616715,"sku":"YLJHP100T750","price":0.0,"currency_code":"MYR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0716\/4405\/3643\/files\/HP-100-4_4174e38c-e5e5-43c9-8aa3-4f0cf33bf64e.jpg?v=1764854000"},{"product_id":"ylj-hp-l","title":"400°C Max. 40T Large Hydraulic Laminating Hot Press with Optional 15\" or 24\" Square Platen - YLJ-HP-L","description":"YLJ-HP-L is a large lamination hot press, which consists of a 40T hydraulic press with two heated platens. The temperatures of the heated platens are controlled by two digital temperature controllers separately up to 400°C. The heated platens are made of stainless steel with optional size at 15\"x15\" or 24\"x24\". Water cooling jackets are installed with the heating platen that allows the heated plates to get faster cooling. One pressure gauge (300 kN) is also mounted to monitor the pressure applied on the platen. It is an excellent tool to prepare polymer and ceramic samples. SPECIFICATIONS: Hydraulic Press Hydraulic pump and hydraulic cylinder are separated for easy replacement Max. Force: 40T Manual operation Max. Working Pressure The actual force applied to the Hydraulic Cylinder (Ton) equal to the force applied to your working piece For calculating the actual pressure applied on the working piece, please follow the equations below: P = T\/(πr^2) x g x 10 P: Pressure (MPa) applied to your working piece T: Force (Ton) applied to the Hydraulic Cylinder g: Standard gravity. g ≈ 9.8 m\/s 2 π: ~3.14 r: Radius (cm) of the working piece *1 Metric Ton = 1000 kg; 1 MPa ≈ 10 kgf\/cm 2 Pressure Gauge Measuring Accuracy is +\/-1.25 kN Heated Platen Area Platen Area: two sizes to choose from product option 381 mm x 381 mm (15\"x15\") 610 mm x 610 mm ( 24\"x24\") Material: SS304 Surface: Flattening with CNC grinding Max. Travel Distance 120 mm Do not raise the bottom cylinder (piston) more than it's maximum traveling distance (80 mm) Pressing Plate Max. Opening Height 120 mm Max. Working Temperature 400°C continuous with water cooling Heating Rate \u0026amp; Cooling Rate ≤ 2°C\/min Water Cooling Jacket Two water cooling jackets are built on the back of the top and bottom heating plate separately with 1\/4\" water pipe connectors. Such a configuration allows you to cool the sample as soon as the hot pressing process is completed. one 16L\/minute recirculating water chiller is included for cooling hot platens. (Pic. 1) SS 304 Protection door is included An electric hydraulic pump can also be applied for automatic pressure control. (Pic below 2) However, the pumping time may take 20 minutes Pic. 1 Pic. 2 Temperature Control Two digital controllers are installed in one box with 30 segments programmable and auto-tune faction Temperature accuracy ±2°C. Power Requirement 208 - 240 VAC, 50\/60Hz, single phase 3.5 KW max. for 15\"x15\" heating platen 10KW Max. for 24\"x24\" heating platen Compliance CE Certified for the whole furnace NRTL (UL 61010) or CSA Certification is available upon request, additional charges will apply\u003cbr\u003e\u003cbr\u003e\u003ctable border=\"1\" cellpadding=\"1\" cellspacing=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eHydraulic Press\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eHydraulic pump and hydraulic cylinder are separated for easy replacement\u003c\/li\u003e\n\u003cli\u003eMax. Force: 40T\u003c\/li\u003e\n\u003cli\u003eManual operation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Working Pressure\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eThe actual force applied to the Hydraulic Cylinder (Ton) equal to the force applied to your working piece\u003c\/li\u003e\n\u003cli\u003eFor calculating the actual pressure applied on the working piece, please follow the equations below:\u003c\/li\u003e\n\u003cli\u003eP = T\/(πr^2) x g x 10\u003c\/li\u003e\n\u003cul\u003e\n\u003cli\u003eP: Pressure (MPa) applied to your working piece\u003c\/li\u003e\n\u003cli\u003eT: Force (Ton) applied to the Hydraulic Cylinder \u003c\/li\u003e\n\u003cli\u003eg: Standard gravity. g ≈ 9.8 m\/s\u003csup\u003e2\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003eπ: ~3.14\u003c\/li\u003e\n\u003cli\u003er: Radius (cm) of the working piece\u003c\/li\u003e\n\u003cli\u003e*1 Metric Ton = 1000 kg; 1 MPa ≈ 10 kgf\/cm\u003csup\u003e2\u003c\/sup\u003e \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure Gauge\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eMeasuring Accuracy is +\/-1.25 kN\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeated Platen Area\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003ePlaten Area: two sizes to choose from product option\u003c\/li\u003e\n\u003cul\u003e\n\u003cli\u003e381 mm x 381 mm (15\"x15\")\u003c\/li\u003e\n\u003cli\u003e610 mm x 610 mm ( 24\"x24\")\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003eMaterial: SS304\u003c\/li\u003e\n\u003cli\u003eSurface: Flattening with CNC grinding \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Travel Distance\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e120 mm \u003c\/li\u003e\n\u003cli style=\"color: rgb(255, 42, 0);\"\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003eDo not raise the bottom cylinder (piston) more than it's maximum traveling distance (80 mm)\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressing Plate Max. Opening Height\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e120 mm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Working Temperature\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e400°C continuous with water cooling\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Rate \u0026amp; Cooling Rate\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e≤ 2°C\/min\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWater Cooling Jacket\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eTwo water cooling jackets are built on the back of the top and bottom heating plate separately with 1\/4\" water pipe connectors. Such a configuration allows you to cool the sample as soon as the hot pressing process is completed. \u003c\/li\u003e\n\u003cli\u003eone 16L\/minute \u003ca href=\"KJ5300\" rel=\"noopener\" target=\"_blank\"\u003erecirculating water chiller\u003c\/a\u003e is included for cooling hot platens. (Pic. 1)\u003c\/li\u003e\n\u003cli\u003eSS 304 Protection door is included \u003c\/li\u003e\n\u003cli\u003eAn electric hydraulic pump can also be applied for automatic pressure control. (Pic below 2)\u003cbr\u003eHowever, the pumping time may take 20 minutes\u003cbr\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"KJ5300\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg alt=\"\" border=\"0\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/KJ5300Front.1_100x100.jpg\" title=\"\"\u003e\u003c\/a\u003e Pic. 1 \u003ca href=\"YLJ-PE\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/IMG20180919150550_100x100.jpg\"\u003e\u003c\/a\u003e   Pic. 2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Control\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eTwo digital controllers are installed in one box with 30 segments programmable and auto-tune faction\u003c\/li\u003e\n\u003cli\u003eTemperature accuracy ±2°C.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Requirement\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e208 - 240 VAC, 50\/60Hz, single phase\u003c\/li\u003e\n\u003cul\u003e\n\u003cli\u003e3.5 KW max. for 15\"x15\" heating platen\u003c\/li\u003e\n\u003cli\u003e10KW Max. for 24\"x24\" heating platen\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompliance\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eCE Certified for the whole furnace\u003c\/li\u003e\n\u003cli\u003eNRTL (UL 61010) or CSA Certification is available upon request, additional charges will apply\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"MTI","offers":[{"title":"15\"x15\" platen","offer_id":44985070715019,"sku":"YLJHP15L","price":0.0,"currency_code":"MYR","in_stock":false},{"title":"24\"x24\" Platen","offer_id":44985070747787,"sku":"YLJHP24L","price":0.0,"currency_code":"MYR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0716\/4405\/3643\/files\/30Twater_4b7c520c-68fc-4c99-92ac-f5ab9fcf2f8d.jpg?v=1764854001"},{"product_id":"ylj-hp300e","title":"200°C Max 40 T Precision Laminating Hot Press (12\" x 12\" area) with Electric Hydraulic Pump - YLJ-HP300E","description":"\u003cp\u003eYLJ-HP300E is a 200°C Max. 40T lamination hot press with an electric hydraulic pump. The temperatures of the heated platens are controlled by two digital temperature controllers separately up to 200°C. The platens (300 x 300 mm area) are made of hardened Cr12MoV alloy with a flat surface. Water cooling jackets are installed on the heating platens that allow the heated platens to get faster cooling. It is an excellent tool for preparing polymer and ceramic samples.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSPECIFICATIONS: \u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ctable border=\"1\" cellpadding=\"1\" cellspacing=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectric Hydraulic Pump\u003cbr\u003e\u003ca href=\"YLJ-PE\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/Pump70Mpa.2_100x100.jpg\"\u003e\u003c\/a\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003ePower: 208-240VAC, 50\/60Hz\u003c\/li\u003e\n\u003cli\u003e180 W AC motor.\u003c\/li\u003e\n\u003cli\u003eProgrammable and automatic pressure control up to 70 MPa\u003c\/li\u003e\n\u003cli\u003eAccuracy: +\/- 0.5MPa in high pumping speed, +\/-0.1 MPa in low pumping speed\u003c\/li\u003e\n\u003cli\u003eBuilt-in digital 30-segment programmable pressure controller to set up multi-step pressurization and dwell time\u003c\/li\u003e\n\u003cli\u003eThe PC software is included for setting up the pressure program and data logging.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Working Pressure\u003c\/td\u003e\n\u003ctd\u003e\n\u003ctable border=\"1\" cellspacing=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge Displayed Pressure Value (MPa)\u003c\/td\u003e\n\u003ctd\u003e 5\u003c\/td\u003e\n\u003ctd\u003e 10 \u003c\/td\u003e\n\u003ctd\u003e 20\u003c\/td\u003e\n\u003ctd\u003e25 \u003c\/td\u003e\n\u003ctd\u003e 30\u003c\/td\u003e\n\u003ctd\u003e 41\u003c\/td\u003e\n\u003ctd colspan=\"13\"\u003e55 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eActual Force Applied on the Hydraulic Cylinder (Ton)\u003c\/td\u003e\n\u003ctd\u003e 5.5\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003ctd\u003e18.5\u003c\/td\u003e\n\u003ctd\u003e22\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003ctd colspan=\"13\"\u003e 40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cul\u003e\n\u003cli\u003eThe actual force applied to the Hydraulic Cylinder (Ton) is equal to the force applied to your working piece\u003c\/li\u003e\n\u003cli\u003eFor calculating the actual pressure applied to the working piece, please follow the equations below:\u003c\/li\u003e\n\u003cli\u003eP = T\/(πr^2) x g x 10\u003c\/li\u003e\n\u003cul\u003e\n\u003cli\u003eP: Pressure (MPa) applied to your working piece\u003c\/li\u003e\n\u003cli\u003eT: Force (Ton) applied to the Hydraulic Cylinder \u003c\/li\u003e\n\u003cli\u003eg: Standard gravity. g ≈ 9.8 m\/s\u003csup\u003e2\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003eπ: ~3.14\u003c\/li\u003e\n\u003cli\u003er: Radius (cm) of the working piece\u003c\/li\u003e\n\u003cli\u003e*1 Metric Ton = 1000 kg; 1 MPa ≈ 10 kgf\/cm\u003csup\u003e2\u003c\/sup\u003e \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLaminating Hot Press\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/YLJ-HP300-1.jpg?v=1706137055\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/YLJ-HP300-1_100x100.jpg\"\u003e\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003ePower: 208 - 240 VAC, 50\/60Hz, single phase\u003c\/li\u003e\n\u003cli\u003e4.5 kW max.\u003c\/li\u003e\n\u003cli\u003e20A circuit breaker is required for 220V, 5' length power cable included, but no plug\u003c\/li\u003e\n\u003cli\u003ePlaten Area: 300 mm x 300 mm (12\"x12\")\u003c\/li\u003e\n\u003cli\u003eMaterial: Harden Cr12MoV alloy\u003c\/li\u003e\n\u003cli\u003eSurface: Flattening with CNC grinding \u003c\/li\u003e\n\u003cli\u003eThe parallelism between two plates: \u0026lt; 0.1 mm within 10\"x10\" area at 200°C\u003c\/li\u003e\n\u003cli\u003ePlate surface roughness: \u0026lt; 2 microns\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Travel Distance\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e80 mm \u003c\/li\u003e\n\u003cli style=\"color: rgb(255, 42, 0);\"\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003eDo not raise the bottom cylinder (piston) more than its maximum traveling distance (80 mm)\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressing Plate Max. Opening Height\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e79 mm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Working Temperature\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e\u003cspan\u003e\u003cspan\u003e500\u003c\/span\u003e\u003cspan\u003e°C Max. \u0026lt; 60 minute\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003e\u003cspan\u003e400\u003c\/span\u003e\u003cspan\u003e°C continuous with water cooling\u003c\/span\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Rate \u0026amp; Cooling Rate\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e≤ 2°C\/min\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWater Cooling Jacket\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eTwo water cooling jackets are built on the back of the top and bottom heating plate separately with 1\/4\" water pipe connectors. Such a configuration allows you to cool the sample as soon as the hot pressing process is completed. \u003c\/li\u003e\n\u003cli\u003eOne \u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003ca href=\"KJ5300\" rel=\"noopener\" style=\"color: rgb(43, 0, 255);\" target=\"_blank\"\u003erecirculating water chiller\u003c\/a\u003e\u003c\/span\u003e is required but not included in the standard package. \u003cbr\u003eBoth the \u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003ca href=\"KJ5000\" rel=\"noopener\" style=\"color: rgb(43, 0, 255);\" target=\"_blank\"\u003eKJ5000 water chiller\u003c\/a\u003e\u003c\/span\u003e and the\u003cspan style=\"color: rgb(43, 0, 255);\"\u003e \u003ca href=\"KJ5300\" rel=\"noopener\" style=\"color: rgb(43, 0, 255);\" target=\"_blank\"\u003eKJ5300 water chiller\u003c\/a\u003e\u003c\/span\u003e would be suitable for the operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/mtimalaysia.com\/products\/KJ5300\" target=\"_blank\" rel=\"noopener\"\u003e\u003cimg src=\"https:\/\/mtimalaysia.com\/cdn\/shop\/files\/EQ-KJ5300_ce014ab5-3a6c-4a5e-8d2c-98d1f582abb1.jpg?v=1764854871\u0026amp;width=3840\" alt=\"Middle Size Digital Temperature Controlled Recirculating Water Chiller with 16L\/min Flow, 6K BTU\/hr -KJ5300\" width=\"80\" height=\"53\"\u003e\u003c\/a\u003e    \u003ca href=\"YLJ-PE\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/cable_100x100.jpg?ts=131834470534072011\"\u003e\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Control\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eTwo digital controllers are installed in one box with 30 segments programmable and auto-tune function\u003c\/li\u003e\n\u003cli\u003eTemperature accuracy ±2°C\u003c\/li\u003e\n\u003cli\u003eThe PC software is included for setting up the temperature profile and data logging.\u003c\/li\u003e\n\u003cli\u003eNote: The PC \u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003ca href=\"MTS01\" rel=\"noopener\" style=\"color: rgb(43, 0, 255);\" target=\"_blank\"\u003esoftware\u003c\/a\u003e\u003c\/span\u003e for setting up the temperature and the pressure are two different software, but both controllers can be connected to a single PC and both software can be run at the same time.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompliance\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eCE Certified for the whole system\u003c\/li\u003e\n\u003cli\u003eNRTL (UL 61010) or CSA Certification is available upon request, additional charges will apply\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication Note\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eThe Hot Press can be placed inside of a glovebox and a temperature controller and the pump will be put outside of the glovebox Pic. 1\u003c\/li\u003e\n\u003cli\u003eThe hot press can be used for measuring the thermo-electric generator module ( top hot and bottom cool) Pic. 2\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/EQ-VGB-6OP-LD_Dimension1.1.jpg?v=1706220208\" target=\"_blank\" rel=\"noopener\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/EQ-VGB-6OP-LD_Dimension1.1.jpg?v=1706220208\" width=\"70\" height=\"72\"\u003e\u003c\/a\u003e Pic. 1\u003cspan\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/Thermo-electric.png?v=1706229260\" target=\"_blank\" rel=\"noopener\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/Thermo-electric.png?v=1706229260\" width=\"75\" height=\"43\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/Thermo-electric.png?v=1706229260\" target=\"_blank\" rel=\"noopener\"\u003e\u003c\/a\u003e\u003c\/span\u003e Pic. 2\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"MTI","offers":[{"title":"Default Title","offer_id":44985070846091,"sku":"YLJHP300E","price":0.0,"currency_code":"MYR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0716\/4405\/3643\/files\/YLJ-HP300-Hidden.1_38d4d4d3-a0f8-4d4f-bfc7-be088f2cc764.jpg?v=1764854002"},{"product_id":"ylj-hp300","title":"500°C Max 30 T Precision Laminating Hot Press (12\" x 12\" area) with Dual Temp. Controller - YLJ-HP300","description":"YLJ-HP300 (updated from YLJ-HP100 ) is 500°C Max. lamination hot press, which consists of a 30T hydraulic press with two heated platens. The temperatures of the heated platens are controlled by two digital temperature controllers separately up to 500°C . The platens ( 300 x 300 mm area) are made of hardened Cr12MoV alloy with a flat surface. Water cooling jackets are installed with the heating platen that allows the heated plate to get faster cooling. One pressure gauge (300 kN) is also mounted to monitor the pressure applied on the plate. It is an excellent tool to prepare polymer and ceramic samples, and SOEC cells (solid-oxide electrolyzer cells). SPECIFICATIONS: Hydraulic Press The hydraulic pump and hydraulic cylinder are separated for easy replacement Max. Force: 30T Manual operation Max. Working Pressure Gauge Displayed Pressure Value (MPa) 5 10 20 25 30 41 Actual Force Applied on the Hydraulic Cylinder (Ton) 5.5 8 15 18.5 22 30 The actual force applied to the Hydraulic Cylinder (Ton) equal to the force applied to your working piece For calculating the actual pressure applied on the working piece, please follow the equations below: P = T\/(πr^2) x g x 10 P: Pressure (MPa) applied to your working piece T: Force (Ton) applied to the Hydraulic Cylinder g: Standard gravity. g ≈ 9.8 m\/s 2 π: ~3.14 r: Radius (cm) of the working piece *1 Metric Ton = 1000 kg; 1 MPa ≈ 10 kgf\/cm 2 Pressure Gauge Measuring Accuracy is +\/-1.25 kN Heated Platen Area Platen Area: 300 mm x 300 mm (Nominal 12\"x12\") Material: Harden Cr12MoV alloy Surface: Flattening with CNC grinding The parallelism between two plates: \u0026lt; 0.1 mm within 10\"x10\" area at 500°C Plate surface roughness: \u0026lt; 2 microns Max. Travel Distance 80 mm Do not raise the bottom cylinder (piston) more than it's maximum traveling distance (80 mm) Pressing Plate Max. Opening Height 79 mm Max. Working Temperature 500°C Max within 60 minutes 400°C continuous with water cooling Heating Rate \u0026amp; Cooling Rate ≤ 2°C\/min Water Cooling Jacket Two water cooling jackets are built on the back of the top and bottom heating plate separately with 1\/4\" water pipe connectors. Such a configuration allows you to cool the sample as soon as the hot pressing process is completed. One recirculating water chiller is required but not included in the standard package. KJ5300 water chiller would be suitable for the operation. （Pic.1) The electric hydraulic pump can be paired with the laminator for automatic pressure control. (Pic 3-4) However, the pumping time may take 15 minutes. Pic.1 Pic.2 Pic.3 Pic.4 Temperature Control Two digital controllers are installed in one box with 30 segments programmable and auto-tune faction Temperature accuracy ±2°C The computer software is included for setting up the temperature profile and data logging (not for pressure). Power Requirement 208 - 240 VAC, 50\/60Hz, single phase 4.5 kW max. 20 A circuit breaker is required for 220 V, 5' length power cable included, but no plug Compliance CE Certified for the whole furnace NRTL (UL 61010) or CSA Certification is available upon request, additional charges will apply Application Note The Hot Press can be located inside of a glovebox and a temperature controller and the pump will be put outside of the glove box Pic. 1 The hot press can be used for measuring the thermo-electric generator module ( top hot and bottom cool) Pic. 2 Pic. 1 Pic. 2\u003cbr\u003e\u003cbr\u003e\u003ctable border=\"1\" cellpadding=\"1\" cellspacing=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eHydraulic Press\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eThe hydraulic pump and hydraulic cylinder are separated for easy replacement\u003c\/li\u003e\n\u003cli\u003eMax. Force: 30T\u003c\/li\u003e\n\u003cli\u003eManual operation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Working Pressure\u003c\/td\u003e\n\u003ctd\u003e\n\u003ctable border=\"1\" cellspacing=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge Displayed Pressure Value (MPa)\u003c\/td\u003e\n\u003ctd\u003e 5\u003c\/td\u003e\n\u003ctd\u003e 10 \u003c\/td\u003e\n\u003ctd\u003e 20 \u003c\/td\u003e\n\u003ctd\u003e25\u003c\/td\u003e\n\u003ctd\u003e30 \u003c\/td\u003e\n\u003ctd colspan=\"7\"\u003e 41\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eActual Force Applied on the Hydraulic Cylinder (Ton)\u003c\/td\u003e\n\u003ctd\u003e 5.5\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003ctd\u003e18.5\u003c\/td\u003e\n\u003ctd\u003e22\u003c\/td\u003e\n\u003ctd colspan=\"7\"\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cul\u003e\n\u003cli\u003eThe actual force applied to the Hydraulic Cylinder (Ton) equal to the force applied to your working piece\u003c\/li\u003e\n\u003cli\u003eFor calculating the actual pressure applied on the working piece, please follow the equations below:\u003c\/li\u003e\n\u003cli\u003eP = T\/(πr^2) x g x 10\u003c\/li\u003e\n\u003cul\u003e\n\u003cli\u003eP: Pressure (MPa) applied to your working piece\u003c\/li\u003e\n\u003cli\u003eT: Force (Ton) applied to the Hydraulic Cylinder \u003c\/li\u003e\n\u003cli\u003eg: Standard gravity. g ≈ 9.8 m\/s\u003csup\u003e2\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003eπ: ~3.14\u003c\/li\u003e\n\u003cli\u003er: Radius (cm) of the working piece\u003c\/li\u003e\n\u003cli\u003e*1 Metric Ton = 1000 kg; 1 MPa ≈ 10 kgf\/cm\u003csup\u003e2\u003c\/sup\u003e \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure Gauge\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eMeasuring Accuracy is +\/-1.25 kN\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeated Platen Area\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003ePlaten Area: 300 mm x 300 mm (Nominal 12\"x12\")\u003c\/li\u003e\n\u003cli\u003eMaterial: Harden Cr12MoV alloy\u003c\/li\u003e\n\u003cli\u003eSurface: Flattening with CNC grinding \u003c\/li\u003e\n\u003cli\u003eThe parallelism between two plates: \u0026lt; 0.1 mm within 10\"x10\" area at 500°C\u003c\/li\u003e\n\u003cli\u003ePlate surface roughness: \u0026lt; 2 microns\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Travel Distance\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e80 mm \u003c\/li\u003e\n\u003cli style=\"color: rgb(255, 42, 0);\"\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003eDo not raise the bottom cylinder (piston) more than it's maximum traveling distance (80 mm)\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressing Plate Max. Opening Height\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e79 mm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Working Temperature\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e500°C Max within 60 minutes\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e400°C continuous with water cooling\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Rate \u0026amp; Cooling Rate\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e≤ 2°C\/min\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWater Cooling Jacket\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eTwo water cooling jackets are built on the back of the top and bottom heating plate separately with 1\/4\" water pipe connectors. Such a configuration allows you to cool the sample as soon as the hot pressing process is completed. \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eOne\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"KJ5300\" rel=\"noopener\" target=\"_blank\"\u003erecirculating water chiller\u003c\/a\u003e\u003cspan\u003e\u003cspan\u003e \u003c\/span\u003eis required but not included in the standard package. \u003cspan\u003e \u003c\/span\u003e\u003ca href=\"KJ5300\" rel=\"noopener\" target=\"_blank\"\u003eKJ5300 water chiller\u003c\/a\u003e\u003cspan\u003e would be suitable for the operation. （Pic.1)\u003c\/span\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eThe electric hydraulic pump can be paired with the laminator for automatic pressure control. (Pic 3-4)\u003cbr\u003eHowever, the pumping time may take 15 minutes.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003e\u003cspan\u003e\u003cspan\u003e     \u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/30Twater.jpg?v=1706209432\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/30Twater_100x100.jpg?v=1706209432\" style=\"margin-bottom: 16px; float: none;\" title=\"\"\u003e\u003c\/a\u003ePic.1\u003ca href=\"KJ5300\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg height=\"54\" src=\"https:\/\/mti-kjgroup.com\/images\/products\/thumb\/KJ5300Front.1.jpg\" width=\"81\"\u003e\u003c\/a\u003e  Pic.2\u003ca href=\"YLJ-HP300E\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg border=\"0\" class=\"product-list-img\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/YLJ-HP300-Hidden.1_100x100.jpg?v=1706210377\" style=\"margin-bottom: 16px; float: none;\" title=\"\"\u003e\u003c\/a\u003e\u003cspan\u003e  Pic.3\u003ca href=\"YLJ-PE\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/products\/Pump70Mpa.2_100x100.jpg?v=1709263258\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003c\/a\u003ePic.4\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003ca href=\"..\/..\/..\/YLJ-PE.aspx\" style=\"font-size: 0.875rem;\"\u003e\u003c\/a\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Control\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eTwo digital controllers are installed in one box with 30 segments programmable and auto-tune faction\u003c\/li\u003e\n\u003cli\u003eTemperature accuracy ±2°C\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eThe computer\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"MTS01\" rel=\"noopener\" target=\"_blank\"\u003esoftware\u003c\/a\u003e\u003ca href=\"https:\/\/mti-kjgroup.com\/EQ-MTS01.aspx\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/a\u003eis included for setting up the temperature profile and data logging (not for pressure).\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Requirement\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e208 - 240 VAC, 50\/60Hz, single phase\u003c\/li\u003e\n\u003cli\u003e4.5 kW max.\u003c\/li\u003e\n\u003cli\u003e20 A circuit breaker is required for 220 V, 5' length power cable included, but no plug\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompliance\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eCE Certified for the whole furnace\u003c\/li\u003e\n\u003cli\u003eNRTL (UL 61010) or CSA Certification is available upon request, additional charges will apply\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication Note\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eThe Hot Press can be located inside of a glovebox and a temperature controller and the pump will be put outside of the glove box Pic. 1\u003c\/li\u003e\n\u003cli\u003eThe hot press can be used for measuring the thermo-electric generator module ( top hot and bottom cool) Pic. 2\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/EQ-VGB-6OP-LD_Dimension1.1.jpg?v=1706220208\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/EQ-VGB-6OP-LD_Dimension1_100x100.jpg\"\u003e\u003c\/a\u003e Pic. 1 \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/Thermo-electric.png?v=1706229260\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/Thermo-electric_100x100.png\"\u003e\u003c\/a\u003e Pic. 2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e, \u003ctable border=\"1\" cellspacing=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge Displayed Pressure Value (MPa)\u003c\/td\u003e\n\u003ctd\u003e 5\u003c\/td\u003e\n\u003ctd\u003e 10 \u003c\/td\u003e\n\u003ctd\u003e 20 \u003c\/td\u003e\n\u003ctd\u003e25\u003c\/td\u003e\n\u003ctd\u003e30 \u003c\/td\u003e\n\u003ctd colspan=\"7\"\u003e 41\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eActual Force Applied on the Hydraulic Cylinder (Ton)\u003c\/td\u003e\n\u003ctd\u003e 5.5\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003ctd\u003e18.5\u003c\/td\u003e\n\u003ctd\u003e22\u003c\/td\u003e\n\u003ctd colspan=\"7\"\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"MTI","offers":[{"title":"Default Title","offer_id":44985070944395,"sku":"YLJHP300","price":0.0,"currency_code":"MYR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0716\/4405\/3643\/files\/YLJ-HP300_Main_cbc48bd7-4a3a-47e7-b6c5-42cfa73b0f8d.jpg?v=1764854003"},{"product_id":"ylj-hp-100e","title":"5T Precision Electric Mechanic Laminating Heating Press (500°C Max, 135x135 mm) - YLJ-HP-100E","description":"YLJ-HP-100E is a 5T max. electric mechanical flat-panel hot press (hydraulic oil-free), which is targeted for the welding or film transfer of wafers, which can handle the maximum sample size: 135mm × 135mm × 40 mm, the maximum operating temperature is 500°C, and the sample can be applied to a maximum pressure of 5T. It is suitable for pressing ceramics, new materials, new energy, superconducting, building materials, and other field sample preparations and materials. Also, it can be used to measure the pressure variation of pouch-type solid-state batteries during battery charging and discharging. 750°C Max version is available upon request.  The compact hot press can be put into a glovebox . Reference article: Nature:  Realization of 2D metals at the ångström Thickness Limit。 SPECIFICATIONS: Power Power consumption 3700W Voltage: 220VAC, 50Hz Heating System Two 135mm*135mm heating platforms, made of heat-resistant mold steel, can withstand a maximum temperature of 500°C (\u0026lt;30min); Maximum sample size : 135*135*40mm Flatness (the upper and lower heating plate in cold state) : ≤ 0.02mm (within the range of 100*100mm) Heating elements : 8 450W U-shaped heating tubes are installed inside the heating platform (4 on the upper and lower). Precise temperature control system : Control each heating platform respectively, up to 30 segments temp control programs can be set with ±5°C accuracy ( ±3°C at a constant temperature of 500°C) Continuous working temperature : 450 Recommended heating rate : 5\/min The temperature control system adopts PID mode for temperature adjustment and has overheating and couple break protection. The three-color warning light on the device will warn you in overtemperature conditions. Pressing System Upper ball screw movable distance : 40mm Pressure display range : 1.00-5000.00 kg Pressure control range : 3-5000Kg with ±3 kg Pressure time : 1-9999min Pressurization modes : two pressuring modes are selectable: Automatic : When the pressure value reaches the target value, a continuous pressure will be applied by the device to keep the pressure at the constant of the set value with accuracy: ±3kg. Manual : Presetting pressure at a fixed value, then you can measure the pressure change of solid-state battery during charging-discharging Programmable Control By connecting the control system, the heating segments, pressure size, and pressure retention time can be programmed. And the data displayed on the touch screen is more intuitive and convenient and fast. Application Note: This pressure is designed for using an insider glovebox with inert gas, including Ar gas One KF 40 feedthrough will be needed if you put the temperature control box outside the glovebox, which is available upon request at the extra cost. Water Chiller (Optional) Upper and lower platens are water-cooled, which prevents the press from overheating and provides rapid cooling. A water chiller is required but not included. MTI's circulating Water Chiller KJ5000 is available. Controlling Software(Optional) Connect to the computer to set the parameters to control the equipment via PC. The pressure curve shown in the software is more intuitive, and data can be exported for the comparison of multiple experiments. This flat hot press also can connect to a battery analyzer to measure the pressure variation of solid-state batteries during the charging and discharging of pouch cells. Compliance CE Certified NRTL or CSA certification is available at an extra cost\u003cbr\u003e\u003cbr\u003e\u003ctable border=\"1\" cellpadding=\"1\" cellspacing=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003ePower\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan lang=\"ZH-CN\"\u003ePower consumption\u003c\/span\u003e 3700W \u003cspan lang=\"ZH-CN\"\u003e\u003cbr\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eVoltage: 220VAC, 50Hz\u003cspan lang=\"ZH-CN\"\u003e\u003cbr\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003e Heating System\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003eTwo 135mm*135mm heating platforms, made of heat-resistant mold steel, can withstand a maximum temperature of 500°C (\u0026lt;30min);\u003cbr\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum sample size\u003c\/strong\u003e: 135*135*40mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlatness (the upper and lower heating plate in cold state)\u003c\/strong\u003e: ≤ 0.02mm (within the range of 100*100mm)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeating elements\u003c\/strong\u003e: 8 450W U-shaped heating tubes are installed inside the heating platform (4 on the upper and lower). \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrecise temperature control system\u003c\/strong\u003e: Control each heating platform respectively, up to 30 segments temp control programs can be set with ±5°C accuracy ( ±3°C at a constant temperature of 500°C)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContinuous working temperature\u003c\/strong\u003e: 450\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRecommended heating rate\u003c\/strong\u003e: 5\/min\u003c\/li\u003e\n\u003c\/ul\u003e\nThe temperature control system adopts PID mode for temperature adjustment and has overheating and couple break protection. The three-color warning light on the device will warn you in overtemperature conditions.\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressing System\u003cbr\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eUpper ball screw movable distance\u003c\/strong\u003e: 40mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePressure display range\u003c\/strong\u003e: 1.00-5000.00 kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePressure control range\u003c\/strong\u003e: 3-5000Kg with ±3 kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePressure time\u003c\/strong\u003e: 1-9999min\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePressurization modes\u003c\/strong\u003e: two pressuring modes are selectable:\u003c\/li\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomatic\u003c\/strong\u003e: When the pressure value reaches the target value, a continuous pressure will be applied by the device to keep the pressure at the constant of the set value with accuracy: ±3kg.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManual\u003c\/strong\u003e: \u003cspan style=\"color: rgb(255, 42, 0);\"\u003ePresetting pressure at a fixed value, then you can measure the pressure change of solid-state battery during charging-discharging\u003c\/span\u003e \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProgrammable Control\u003cbr\u003e\n\u003cdiv\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/YLJ-HP-100E_CC.png?v=1706137055\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/YLJ-HP-100E_CC_100x100.png\"\u003e\u003c\/a\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003eBy connecting the control system, the heating segments, pressure size, and pressure retention time can be programmed. And the data displayed on the touch screen is more intuitive and convenient and fast.\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/YLJ-HP-100E_CC.png\"\u003e\u003cbr\u003e\u003c\/a\u003e \u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication Note:\u003cbr\u003e\n\u003cdiv\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/10T-HP-glove.jpg?v=1706209409\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg alt=\"\" height=\"57\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/10T-HP-glove_100x100.jpg\" width=\"88\"\u003e\u003c\/a\u003e   \u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eThis pressure is designed for using an insider glovebox with inert gas, including Ar gas\u003c\/li\u003e\n\u003cli\u003eOne KF 40 feedthrough will be needed if you put the temperature control box outside the glovebox, which is available upon request at the extra cost.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWater Chiller (Optional)\u003cbr\u003e\n\u003cdiv\u003e\u003ca href=\"KJ5000\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/EQ-KJ5000-220-hide.1_100x100.jpg\"\u003e\u003c\/a\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cli\u003eUpper and lower platens are water-cooled, which prevents the press from overheating and provides rapid cooling. \u003c\/li\u003e\n\u003cli\u003eA water chiller is required but not included. \u003c\/li\u003e\n\u003cli\u003eMTI's circulating Water Chiller \u003ca href=\"KJ5000\" rel=\"noopener\" target=\"_blank\"\u003eKJ5000 \u003c\/a\u003e\u003ca href=\"..\/..\/..\/DigitalTempeatureControlledRecirculatingWaterChiller-EQ-KJ5000.aspx\"\u003e\u003c\/a\u003eis available. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControlling Software(Optional)\n\u003cdiv\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/YLJ-HP-100E_sw.jpg?v=1706137055\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg alt=\"\" height=\"56\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/YLJ-HP-100E_sw_100x100.jpg\" width=\"92\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/Battery-Press.jpg?v=1706209833\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg alt=\"\" height=\"50\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/Battery-Press_100x100.jpg\" width=\"78\"\u003e\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cli\u003eConnect to the computer to set the parameters to control the equipment via PC. The pressure curve shown in the software is more intuitive, and data can be exported for the comparison of multiple experiments. \u003c\/li\u003e\n\u003cli\u003eThis flat hot press also can connect to a battery analyzer to measure the pressure variation of solid-state batteries during the charging and discharging of pouch cells.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompliance\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eCE Certified\u003c\/li\u003e\n\u003cli\u003eNRTL or CSA certification is available at an extra cost\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"MTI","offers":[{"title":"Press only","offer_id":44985071009931,"sku":"YLJ-HP-100E","price":0.0,"currency_code":"MYR","in_stock":false},{"title":"Press + Water Chiller + Software","offer_id":44985071042699,"sku":"YLJ-HP-100EALL","price":0.0,"currency_code":"MYR","in_stock":false},{"title":"Press + Water Chiller","offer_id":44985071075467,"sku":"YLJ-HP-100EWC","price":0.0,"currency_code":"MYR","in_stock":false},{"title":"Press + Battery analyzer","offer_id":44985071108235,"sku":"YLJ-HP-100ECS","price":0.0,"currency_code":"MYR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0716\/4405\/3643\/files\/YLJ-HP-100E_main.1.jpg?v=1764854004"}],"url":"https:\/\/mtimalaysia.com\/collections\/hot-lamination.oembed","provider":"MTI Malaysia \u0026 Indonesia","version":"1.0","type":"link"}